Connecting The Unit - BGM Grouping (Matrix)
+
DC 24V
5
TIME OUT 5 MIN
LINE / MIC OUTPUT
MASTER / SLAVE
0
L
S
M M
+
DC 24V
5
TIME OUT 5 MIN
LINE / MIC OUTPUT
MASTER / SLAVE
0
L
S
M
M
Music
Music
Matrix
Group 1
Group 8
Paging data & audio
Master
Slave
1
8
57
64
Audio &
Data Link
+
DC 24V
5
TIME OUT 5 MIN
LINE / MIC OUTPUT
MASTER / SLAVE
0
L
S
M
M
+
DC 24V
5
TIME OUT 5 MIN
LINE / MIC OUTPUT
MASTER / SLAVE
0
L
S
M
M
To power amp. input (Group 1)
From amplifier output
Unit 1 (master)
to zone speaker
(zone 1 & 8)
Output from
matrix
(Group 1)
(Group 2)
Unit 2 (slave)
to zone speaker
(zone 9 & 16)
Link
Application Note:
1) This configuration shall be and whenever grouping of zones is required.
e.g: zone 1 to zone 8 to have same BGM input, Group 1 and so forth.
2) Paging made to a zone in the same group shall mute other zone within the group but would not interrupt zones in
other groups.
3) This setup would normally be used together with matrix controller.
4) Use of DA2208 at paging mic audio output is required if more than 6 amplifiers are installed in the system.
Detailed BGM Grouping
BG
M
2
TD6080 | 8 CH DECODER / ZONE SELECTOR
PAGE 7
To power amp. input (Group 2)