background image

Connecting The Unit - BGM Grouping (Matrix)

+

DC 24V

5

TIME OUT 5 MIN
LINE / MIC OUTPUT
MASTER / SLAVE

0

L

S

M M

+

DC 24V

5

TIME OUT 5 MIN
LINE / MIC OUTPUT
MASTER / SLAVE

0

L

S

M

M

Music

Music

Matrix

Group 1

Group 8

Paging data & audio

Master

Slave

1
8

57

64

Audio & 

Data Link

+

DC 24V

5

TIME OUT 5 MIN
LINE / MIC OUTPUT
MASTER / SLAVE

0

L

S

M

M

+

DC 24V

5

TIME OUT 5 MIN
LINE / MIC OUTPUT
MASTER / SLAVE

0

L

S

M

M

To power amp. input (Group 1)

From amplifier output

Unit 1 (master)

to zone speaker

(zone 1 & 8)

Output from 

matrix

(Group 1)

(Group 2)

Unit 2 (slave)

to zone speaker

(zone 9 & 16)

Link

Application Note:

1) This configuration shall be and whenever grouping of zones is required.

    e.g:  zone 1 to zone 8 to have same BGM input, Group 1 and so forth.

2) Paging made to a zone in the same group shall mute other zone  within the group but would not interrupt zones in 

    other groups.

3) This setup would normally be used together with matrix controller.

4) Use of DA2208 at paging mic audio output is required if more than 6 amplifiers are installed in the system.

Detailed BGM Grouping

BG

M

 2

TD6080 | 8 CH DECODER / ZONE SELECTOR

PAGE 7

To power amp. input (Group 2)

Summary of Contents for TD6080

Page 1: ...cost reduction can be achieved due to lower unit count and space requirement as compared to setup using zone decoder and zone selector We appreciate that you read through the manual to avoid any mish...

Page 2: ...o page 7 6 MIXER INPUT 7 AUDIO OUTPUT Audio output from the decoder is balanced line output level RJ45 connector consists of audio data and power with the following pin configuration Pin 1 Data A Pin...

Page 3: ...cy paging mic with dry contact can be connected here which shall trigger the built in relay when pressed This shall then provide a dry contact in which would enable the installer to apply several func...

Page 4: ...E MAX MIN TONE CTRL CH5 CH6 CH4 SIG IN SIG IN SIG IN MAX MIN MAX MIN MIN CH3 CH1 CH2 SIG IN SIG IN MAX MIN MAX MIN MAX MIN MAX AUX SIG IN a m pe re s MX 2 1 2 2 O I MENU a m pe re s O I POWER QP2500 U...

Page 5: ...of PD2800 Remote location DC 24V 5 TIME OUT 5 MIN LINE MIC OUTPUT MASTER SLAVE 0 L S M M SPEAKERS TD6080 MX2222 QP2500 EP1200A Zone 1 100V TD6080 8 CH DECODER ZONE SELECTOR PAGE 5 Zone 8 Select Mic D...

Page 6: ...00 2800 PD2400 2800 Note 1 Use EX1103A if more than one PD2400 2800 are available in the system The single output RJ45 can be directly connected to TD6080 mic input port 2 A higher priority mic shall...

Page 7: ...speaker zone 1 8 Output from matrix Group 1 Group 2 Unit 2 slave to zone speaker zone 9 16 Link Application Note 1 This configuration shall be and whenever grouping of zones is required e g zone 1 to...

Page 8: ...PAGING CLIENT DC 24V 5 TIME OUT 5 MIN LINE MIC OUTPUT MASTER SLAVE 0 L S M M TD6080 Network Switch QP2500 PAGE 8 TD6080 8 CH DECODER ZONE SELECTOR PD2800 PD SERIES PAGING MIC INPUT OUTPUT EX2800 Line...

Page 9: ...INE MIC OUTPUT MASTER SLAVE 0 L S M M 1 8 ON 2 ON 1 2 ON Z 1 Z 8 Z 9 Z 16 Z 17 Z 24 master slave slave Set unit address example 10000 0000 Zone 1 to 8 DIP Switch 8 ON 01000 0000 Zone 9 to 16 DIP Switc...

Page 10: ...4V DC ve Note Trigger of ALL CALL button at TD6080 front panel shall ON all zones but would not be able to override volume controllers This is to avoid unnecessary announcement or BGM to be broadcaste...

Page 11: ...imension WxHx D Weight 24V DC 6W 250 mA 500W at 100V line 31 Unit 248 zone 2 8 8 Front panel switch remote Individual zone switch Individual All Call Local zone selection bypassed when remote trigger...