SQ9715 SEQUENTIAL POWER SWITCHER

Cascading SQ9715

2  units  of  SQ9715  can  be  linked  to  form  a  14 

channel power distribution setup. Setting has to 

be made to make one of them as Master ( Ch 1 

to 7 ) and the other ( Ch 8 to 14 ) as slave. In 

cascading mode, the ON or OFF function is done 

through the Master unit.

Note  :  Both  units  must  have  common  body 

grounding

REM

TRIG

8

: CH 7 DELAY

9

: OFF (MAS) / ON (SLAVE)

10 : ON / OFF BYPASS

1~7 : CH 1 ~ CH 7

ON

Another Quality Product From

C

CASC

LINK

1 2 3 4 5 6 7 8 9 10

REM

TRIG

8

: CH 7 DELAY

9

: OFF (MAS) / ON (SLAVE)

10 : ON / OFF BYPASS

1~7 : CH 1 ~ CH 7

ON

Another Quality Product From

CASC

LINK

1 2 3 4 5 6 7 8 9 10

link cable

ON

ON

1 2 3 4 5 6 7 8 9 10

1 2 3 4 5 6 7 8 9 10

MASTER UNIT

SLAVE UNIT

Setting for DIP 8 optional

When  it  is  necessary  to  power  up  the 

equipments  from  a  remote  location  (  ie  control 

room  located  a  distance  away  from  main 

equipment  ),  a  simple  connection  with  a 

noiseless switch is all it requires. The maximum 

distance  shall  not  exceed  300m  .  For  far 

distance,  please  connect  a  capacitor  of  0.1  uF 

accross the contact point of the switch as shown.

REM
TRIG

8

: CH 7 DELAY

9

: OFF (MAS) / ON (SLAVE)

10 : ON / OFF BYPASS

1~7 : CH 1 ~ CH 7

ON

Another Quality Product From

C

CASC

LINK

1 2 3 4 5 6 7 8 9 10

ON

1 2 3 4 5 6 7 8 9 10

DIP SETTING

REMOTE SWITCH

0.1uF CAP

300M

DIP Switching

8     : CH 7 DELAY
9     : OFF (MAS) / ON (SLAVE)
10   : ON / OFF BYPASS

1~7 : CH 1 ~ CH 7

ON

Another Quality Product From

1 2 3 4 5 6 7 8 9 10

DIP Switch 1 ~ 7

Select OFF to bypass channel (isolate power)

DIP Switch 8

Select ON to enable channel 7 into delay OFF mode for 2 minutes

DIP Switch 9

For use in Cascading mode. For master unit (Ch 1 to 7), select OFF position and for 

slave unit (Ch 8 to 14) switch to ON. The ON/OFF and lock switch would be disable in 

the Slave unit.

DIP Switch 10.

Select  ON  to  allow  the  ON/OFF  switch  active  whereas  OFF  disable  it.  This  is 

applicable in remote switching mode.

To Trigger SQ9715 Remotely

Summary of Contents for SQ9715

Page 1: ...ut Audio Visual installations as well Powering of array of equipment had been made simpler and safer prolonging the life span of the delicate equipment such as projectors amplifiers etc Again thank you for trusting another appliance from Amperes and experience the countless features we have to offer INSTRUCTION MANUAL SQ9715 Sequential Power Switcher amperes ...

Page 2: ...ch at rear panel Pressing LOCK and ON OFF simultaneously would disable the ON OFF switch and shall prevent accidental triggering to the unit LOCK LED would flash when the unit is in lock mode To unlock press LOCK and ON OFF simultaneously Lighted LED indicates active channel When the unit is in LOCK mode this LED would flash This LED indicates the presence of incoming mains supply Connect the supp...

Page 3: ... power up the system press the ON OFF button at front panel Every channel will be activated in steps and is shown at the LED indicators After the whole system has been powered up lock the unit by pressing LOCK and the ON OFF switch simultaneously Repeat the same procedure to unlock To power down press the ON OFF switch and system is shutting down from CH7 to CH1 in steps Always switch off the main...

Page 4: ... 2 CH 3 CH 4 CH 5 CH 6 CH 7 NON DELAY SOUND SYSTEM INSTALLATION 1 2 3 4 5 6 7 8 9 10 DIP SETTING Power amp connected to channel 7 MOTOR SCREEN DVD VCR VISUALISER UNUSED UNUSED LCD PROJECTOR CH 1 CH 2 CH 3 CH 4 CH 5 CH 6 CH 7 DELAY ACTIVE PROJECTION SYSTEM INSTALLATION 1 2 3 4 5 6 7 8 9 10 DIP SETTING LCD Projector connected to channel 7 with delay active ...

Page 5: ...away from main equipment a simple connection with a noiseless switch is all it requires The maximum distance shall not exceed 300m For far distance please connect a capacitor of 0 1 uF accross the contact point of the switch as shown REM TRIG 8 CH 7 DELAY 9 OFF MAS ON SLAVE 10 ON OFF BYPASS 1 7 CH 1 CH 7 ON Another Quality Product From C CASC LINK 1 2 3 4 5 6 7 8 9 10 ON 1 2 3 4 5 6 7 8 9 10 DIP S...

Page 6: ...ojector powering Lock mode to avoid incidental switching Built in surge protection Technical Specifications Operating voltage 230 240V AC Power consumption 50 mW without load Output voltage 230 240V AC Max load channel 6A Max total load 15A Output connection IEC female socket Max cascade 2 uts total 14 channels Surge protection L N L E N E Clamping voltage 870V AC Turn on sequence Step 1 to 7 incr...

Page 7: ...e unable to insert the plug into the outlet contact an electrician to replace your obsolete outlet Do not defeat the safety purpose of the plug 9 The power supply cord of the product should be unplugged from the outlet when left unused for a long period of time When unplugging the power supply cord do not pull on the cord but grasp it by the plug 10 Care should be taken so that object do not fall ...

Page 8: ...of the purchaser or the dealer for the period out of use of the unit moreover the warranty does not cover any damages which may be caused to people and things when using the product This warranty certificate is valid only for the described product and is not valid if modifications are made on this certificate or on the identification label applied on the product This warranty covers all the materi...

Reviews: