SQ9715 SEQUENTIAL POWER SWITCHER

Parts Identifications

1.  ON/OFF PUSH SWITCH

2.  LOCK SWITCH

3.  CHANNEL OUTPUT LED

4.  LOCK LED 

5.  MAINS LED

C

1

C

2

C

3

C

4

C

5

C

6

C

7

CHANNEL OUTPUTS
MAX : 5 A / 240 V / CH

THIS UNIT MUST BE EARTHED

RISK OF ELECTRICAL SHOCK

WARNING !

DO NOT OPEN

MAINS : 230V +/-10%  AC 50 / 60HZ

REM
TRIG

8     : CH 7 DELAY
9     : OFF (MAS) / ON (SLAVE)
10   : ON / OFF BYPASS

1~7 : CH 1 ~ CH 7

ON

Another Quality Product From

SQ9

71

5

S

ER. 

NBR

CASC

LINK

1 2 3 4 5 6 7 8 9 10

Front View

Rear View

amperes

1

3

2

4

5

6

7

8 9

10

6.  INCOMING POWER CORD

7.  CHANNEL OUTPUT IEC SOCKETS

8.  REMOTE TRIGGERING PORT

9.  CASCADING LINK

10. DIP SWITCH SETTINGS

Press once to power up or shutting down your system. Each channel would be switched ON or OFF in steps of 2 

seconds  intervals.  LED  indicators  for  isolated  channel  would  not  lit.  Please  refer  to  item  10  on  how  to  isolate  the 

channel. The switch can be bypassed by DIP switch at rear panel.

Pressing LOCK and ON/OFF simultaneously would disable the ON/OFF switch and shall prevent accidental triggering 

to the unit. LOCK LED would flash when the unit is in lock mode. To unlock, press LOCK and ON/OFF simultaneously.

Lighted LED indicates active channel.

When the unit is in LOCK mode, this LED would flash.

This LED indicates the presence of incoming mains supply.

Connect the supply to the unit with approriate fused plug top. This unit must be earthed !.

Use the male IEC plugs provided to connect the equipments to the unit. Please ensure that max load per channel does 

not exceed 5A with total load of 15A maximum.

When remote powering of system is required ( Control room   far away from main  rack ), use a  dry contact switch 

(noiseless) and terminate it to the port. Refer details

.

In the event 2 units of SQ9715 is used in a system, link them with this port. DIP has to be set to identify which unit is 

either Master or Slave. Refer Details.

It is used to select the output functions such as channel isolation, channel 7 delay, unit Master or Slave setting and front 

ON/OFF switch bypass.

Summary of Contents for SQ9715

Page 1: ...ut Audio Visual installations as well Powering of array of equipment had been made simpler and safer prolonging the life span of the delicate equipment such as projectors amplifiers etc Again thank you for trusting another appliance from Amperes and experience the countless features we have to offer INSTRUCTION MANUAL SQ9715 Sequential Power Switcher amperes ...

Page 2: ...ch at rear panel Pressing LOCK and ON OFF simultaneously would disable the ON OFF switch and shall prevent accidental triggering to the unit LOCK LED would flash when the unit is in lock mode To unlock press LOCK and ON OFF simultaneously Lighted LED indicates active channel When the unit is in LOCK mode this LED would flash This LED indicates the presence of incoming mains supply Connect the supp...

Page 3: ... power up the system press the ON OFF button at front panel Every channel will be activated in steps and is shown at the LED indicators After the whole system has been powered up lock the unit by pressing LOCK and the ON OFF switch simultaneously Repeat the same procedure to unlock To power down press the ON OFF switch and system is shutting down from CH7 to CH1 in steps Always switch off the main...

Page 4: ... 2 CH 3 CH 4 CH 5 CH 6 CH 7 NON DELAY SOUND SYSTEM INSTALLATION 1 2 3 4 5 6 7 8 9 10 DIP SETTING Power amp connected to channel 7 MOTOR SCREEN DVD VCR VISUALISER UNUSED UNUSED LCD PROJECTOR CH 1 CH 2 CH 3 CH 4 CH 5 CH 6 CH 7 DELAY ACTIVE PROJECTION SYSTEM INSTALLATION 1 2 3 4 5 6 7 8 9 10 DIP SETTING LCD Projector connected to channel 7 with delay active ...

Page 5: ...away from main equipment a simple connection with a noiseless switch is all it requires The maximum distance shall not exceed 300m For far distance please connect a capacitor of 0 1 uF accross the contact point of the switch as shown REM TRIG 8 CH 7 DELAY 9 OFF MAS ON SLAVE 10 ON OFF BYPASS 1 7 CH 1 CH 7 ON Another Quality Product From C CASC LINK 1 2 3 4 5 6 7 8 9 10 ON 1 2 3 4 5 6 7 8 9 10 DIP S...

Page 6: ...ojector powering Lock mode to avoid incidental switching Built in surge protection Technical Specifications Operating voltage 230 240V AC Power consumption 50 mW without load Output voltage 230 240V AC Max load channel 6A Max total load 15A Output connection IEC female socket Max cascade 2 uts total 14 channels Surge protection L N L E N E Clamping voltage 870V AC Turn on sequence Step 1 to 7 incr...

Page 7: ...e unable to insert the plug into the outlet contact an electrician to replace your obsolete outlet Do not defeat the safety purpose of the plug 9 The power supply cord of the product should be unplugged from the outlet when left unused for a long period of time When unplugging the power supply cord do not pull on the cord but grasp it by the plug 10 Care should be taken so that object do not fall ...

Page 8: ...of the purchaser or the dealer for the period out of use of the unit moreover the warranty does not cover any damages which may be caused to people and things when using the product This warranty certificate is valid only for the described product and is not valid if modifications are made on this certificate or on the identification label applied on the product This warranty covers all the materi...

Reviews: