background image

PMX II LAN Interface

PAGE 4

iPX5500 | ETHERNET COMMUNICATION BOX

Connectivity of iPX5500 and PMX LAN and can be seen at 

the PMX LAN software under the tab: “ Combox  Manager”.

PMX II LAN Interface:

Go to ‘Configuration’ menu and go to ‘Remote Interface’, 

make sure ‘Data Port’ same with web browser setting.

iPX5500 shall require some simple setups, kindly follow the step by step instructions as listed below. The unit shall be 

connected to LAN network for a complete system. The default IP address is 

192.168.0.100

. Login page shall appear and 

the default User ID and Password are both 

“admin”

.

Info / Main Page

Info:

 Providing hardware, network and Application 

information. This shall be the first page once you 

entered the system’s http browser.

Network Configuration:

 For configuration of 

IP address and its related ports.

System configuration:

  For Application 

Settings.

Hardware Information

Firmware Version

Hardware Revision

Serial Number

Device Name

Network Information

MAC Address

IPv4 Address

Subnet Mask

Gateway Address

Application Information

Server IP

Communication Port

Device Setup

Summary of Contents for iPX5500

Page 1: ...quipment with RS485 outputs and remote PC enabling remote monitor ing and controls via Amperes PMX II LAN software It converts RS485 data received from equipment into IP and shall be received by remot...

Page 2: ...e previously would be lost 5 RELAY CONTACT This ports provide a dry contact which can be used to connect E M overriding signal or activate ALL CALL at speaker zone selector 6 EXTERNAL MESSAGE TRIGGER...

Page 3: ...6 ON HIGH CASCADE LOW CHANNEL 8 G INPUT OUTPUT CHANNEL 7 G OUTPUT INPUT CHANNEL 6 G OUTPUT INPUT CHANNEL 5 G OUTPUT INPUT CHANNEL 4 G OUTPUT INPUT CHANNEL 1 STANDBY G G OUTPUT INPUT OUTPUT OPEN LINK L...

Page 4: ...ork for a complete system The default IP address is 192 168 0 100 Login page shall appear and the default User ID and Password are both admin Info Main Page Info Providing hardware network and Applica...

Page 5: ...ime connection mode Low amount Quickly connection to PMX High amount Will take a while before automatically find the PMX and connect to it Server IP To indicate the IP address of the which the connect...

Page 6: ...updated firmware file Ready to upload click Upload button to upload the firmware Updating progress After finish updating firmware the browser automati cally restart System firmware shall be updated o...

Page 7: ...rmware upgrade Operating condition Temperature Humidity Case Dimension WxHxD Weight 24V DC 100 mA RJ 45 100Mb s TCP IP UDP IGMP HTTP UDMP ADP Multicast Note The above specifications are correct at tim...

Page 8: ...ormed by unauthorized personnel or service centres This warranty covers only repairs and replacement of defective parts cost and risks of transportation as well as removal and installation of the prod...

Reviews: