22
8. Insert key into the keyway in
the stub shaft, figure 16.
9. Replace the impeller, impeller
nut and gasket, figure 17.
10. Insert the 3/8” bar into the
stub shaft, figure 18, and torque
the impeller nut to 90 ft-lbs for
LF X-pumps and to 40 ft-lbs for
all other LF pumps.
Figure 16
Figure 18
Figure 17