background image

En-2

3.2. Wiring (sensor wiring)

Remove the screws from the remote sensor, and remove the cover.
Connect the cable to the remote sensor as shown below.
Ensure that the wires do not contact each other.

3.3. Installation

1

  When the cable is attached to the wall

• Remove the material covering the wiring penetration 

(thin material) in the cover of the sensor unit with a pair 
of cutters. The cable passes through this hole. 

• Now the remote sensor on the wall using the screws.

2

  When the cable is buried in the wall

•  Remove the material (thinner than the surrounding material) 

in the wiring hole in the remote sensor using a pair of cutters.

• Drill a hole in the wall for the cable.
•  Seal the area around the cable penetration with putty.

3

  Fit the cover on the remote sensor and screw it in place.

4. WIRING TO AIR-CONDITIONER

Install the wiring to the air-conditioner indoor unit as follows.

1

  Fasten the remote sensor cable onto the indoor electronic control unit. (If necessary, use a supplied screw 

(M4 × 10 mm) and the cable clamp.)

2

  Remove the existing connector and replace it with the remote sensor connector (ensure that the correct connector is used).

• Type 

Ι

• Type 

ΙΙ

• Type 

ΙΙΙ

CN19

R.TH

PCB

CN8

R.TH

(WHT)

CN8

R.TH

(WHT)

3

  The original connector should be insulated to ensure that it does not come into contact with other electrical circuitry.

Remote 
sensor

Cable

Screw 
(M4 × 16 mm)

Mounting hole dimensions

Units: mm (inch)

40 (1-9/16)

55 (2-5/32)

Mounting hole dimensions

ø6 (1/4)~ø10 (25/64)

Units: mm (inch)

Screw 
(M4 × 16 mm)

20

(25/32)

20

(25/32)

1 (1/32)

1 (1/32)

55 (2-5/32)

9366394068-02_IM.indb   2

9366394068-02_IM.indb   2

4/19/2012   1:47:55 PM

4/19/2012   1:47:55 PM

AMP Air Conditioning

www.ampair.co.uk | [email protected]

Reviews: