Ammonit Data Logger Manual
66
Ammonit GmbH / 2005 - 2009
Meteo-32
Connecting sockets of the Data Logger:
1.
Data
6-pin
2.
Supply 5-pin
3.
Wind
12-pin
4.
Meteo 7-pin
Pin assignment:
Pin Data
1
Data input
2
Handshake input
3
Data output
4
do not connect
5
Signal ground
6
Handshake output
Pin Supply
1
Ground / GND
2
Digital output (GND)
3** External supply: + 10 V ... + 24 V
4
RS - 485 / A
5
RS - 485 / B
Pin Wind
A
Signal input / wind speed 1
B
Signal input / wind speed 2
C
Signal input / wind speed 3
D
Wind direction 1 / Potentiometer end E / West
E
Wind direction 1 / Potentiometer start a / East
F
Wind direction 1 / wiper position R / Direction
G
Wind direction 1 / Potentiometer start A / East
H
Anemometer: output + 5V
J
Wind direction 2* / wiper position R / Direction
K
Wind direction 2* / Potentiometer end E / West
L** External supply: + 10 V ... + 24 V
M
Ground / GND
*) Wind direction
2 / Potentiometer start: connect with Ground
**) interconnected pins
Summary of Contents for METEO-32
Page 35: ...Ammonit Data Logger Manual 34 Ammonit GmbH 2005 2009...
Page 47: ...Ammonit Data Logger Manual 46 Ammonit GmbH 2005 2009...
Page 57: ...Ammonit Data Logger Manual 56 Ammonit GmbH 2005 2009...
Page 73: ...Ammonit Data Logger Manual 72 Ammonit GmbH 2005 2009 4 plug Xtend Plan view Data Logger...