3.6 Lubrication and maintenance operations
3.6.17 Cleaning the water separator on the fuel
filter
If the red ring goes up from the bottom, drain the water from
the separator.
Close the stop valve (1).
Unscrew the filter housing (2).
Clean the filter element (3).
Screw in the filter housing back (2)
Open the stop valve (1).
Turn the ignition on. The fuel pump will vent the system
automatically.
Fuel filter cartridge
Order number: 1448216
Do not smoke while working!
Check the water separator for leaks.