24
Bin Count
Displays the status of the bin levels as a percentage. The Bin Count
feature can be calibrated in the
Product Calibration
screen. These
indicators are an approximation based on the calculated meter accu-
mulation and must be properly calibrated in order to properly function.
Ground Speed
Displays Fan speed in RPM. Min and Max alarms can be set in the
System Settings
screen. See System Setup for more information.
Area Counters
Displays total area in
Acres
or
Hectares
.
Pressing the
Area
button will clear the area accumulation.
Seeder UP/Down
Displays the current up or down state of the seeder. If there is a work
switch on the seeder, the
Seeder Up/Down
indicator will change as
the seeder is lifted up or set down. If there is no work switch present
on the seeder, the
Seeder Up/Down
indicator will always refl ect the
down position.
Seeding State
Displays whether the seeder is seeding or not. A
green
indictor will
show when the drill is in the seeding state. Seeding can only occur if
the
Seeder Up/Down
indicator is in the down position, the work switch
softkey is
green
, and speed is present.
Work Switch Softkey
Pressing the
Work Switch Softkey
will turn the seeder on if there is no
automatic work switch installed on the seeder.
If there is an automatic work switch installed on the seeder, pressing
the
Work Switch Softkey
will enable operation of the automatic work
switch.