background image

KS-111E 

 

7/52 

ks-111e_g_en_100 

3.  Technical parameters 

3.1.  System description 

System  functionality  is  determined  by  software  used  in  IP  monitors  and  re-
cording unit. 

Layout  of  components  in  vehicle  you  can  find  in  APPENDIX  A 

–  Location  of 

components.. 

3.2.  System functions 

KS-111E

 has following functions: 

  Viewing of image from cameras on left and right IP monitor. 

  Archiving of images from all twelve cameras with 640 x 480 pixels resolu-

tion with data flow 5 fps (frames per second). 

  IP monitors communicate with VCU 

– sends the lifetime counter to VCU. 

  IP  monitors  communicates  with  display  of  master  control  (MC),  from 

where are picked the scenes and backlight is controlled. 

  For  processing  and  viewing  data  from  recording  unit  is  used  an  Acasys 

Studio software tool. 

Summary of Contents for AIPM1010/A

Page 1: ...ks 111e_g_en_100 KS 111E Camera system Operation manual Version 1 00...

Page 2: ...ll pages must be copied without any changes 2 All redistributed copies must retain the AMiT spol s r o copyright notice and any other notices contained in the documentation 3 This document must not be...

Page 3: ...meras commissioning 14 4 2 1 Camera identification 15 Attaching camera to Ethernet 15 Finding of attached camera through ACM 15 4 2 2 Firmware upgrade 16 4 2 3 Loading of configuration template 18 4 2...

Page 4: ...ng the factory setting 45 Software way of Restoring the factory setting 45 Hardware way of Restoring the factory setting 47 11 2 Meaning of camera LED indicators 48 12 Appendix H USB flash disk PPM2xx...

Page 5: ...ssible powering via communiaction cable Power Over Ethernet Determines the way of viewing information on IP monitor Can contain the following items 1 empty screen 2 camera number to be displayed on IP...

Page 6: ...ment describes putting into operation and setting the 111E KS 111e engine camera system from software point of view Document does not care about mechanical assembly which is solved in Opera tion manua...

Page 7: ...s following functions Viewing of image from cameras on left and right IP monitor Archiving of images from all twelve cameras with 640 x 480 pixels resolu tion with data flow 5 fps frames per second IP...

Page 8: ...disk utilization 95 of overall capa ity Timeout at camera dis connection 5 s SOS state duration 300 s Service access FTP PPM2110 1T 1 x Recording unit with software AIPM1010 A 2 x IP monitor with soft...

Page 9: ...ons in IP monitors Black screen without camera number Video stream blackout Symbol see Fig 1 Video stream blackout symbol No scene is selected Black screen without camera number Scene view 1 8 selecte...

Page 10: ...mmissioning IP monitors commissioning consits of following steps IP address setting up Loading the actual version of an application Any service notebook with installed FTP client file manager Total Co...

Page 11: ...ander Main Menu Click on button New attachment in dialog box Connect to FTP server Fig 3 TC Attaching monitor to FTP server Enter the parameters for attaching to first monitor APPENDIX E Configura tio...

Page 12: ...KS 111E ks 111e_g_en_100 12 52 Host Port APM_ A_IP User name APM_Login Password APM_Password Fig 4 TC Monitor_A parameters Press the button Connect Fig 5 TC Connection to Monitor_A...

Page 13: ...lly 10 to 20 s the communication seems to be for short time frozen This behave is quite comon In case that freezing takes several minutes restart the camera system power supply off and on and repeat t...

Page 14: ..._apm txt File can be downloades through FTP Attach the monitor Chapter 4 1 2 Attaching monitor to FTP server View the app_apm txt file content Application version can be detected from text Fig 7 Verif...

Page 15: ...ubnetwork mask 255 255 255 0 Outgoing gateway do not fill 4 2 1 Camera identification The first step is identification of particular camera There are two scenarios available which can be used for iden...

Page 16: ...l and no camera is found repeat this procedure Camera which has been found is shown in ACM Main window Fig 10 ACM New camera is found 4 2 2 Firmware upgrade Select the camera by left mouse button clic...

Page 17: ...am set Kamery_vvv Firmware Fig 12 Selection of file with firmware By checking the Upgrade device in radio button we can affect the upgrade process when a bulk upgrading of more cameras is made Paralle...

Page 18: ...ecapitulation window is shown which presents a list of upgraded cameras and result of upgrade 4 2 3 Loading of configuration template Select the camera in ACM Main window by left mouse button click Cl...

Page 19: ...00 Fig 15 ACM Looking for template Through item Browse open a next window with list of configuration templates Fig 16 Selection of configuration template Choose the configuration template which is det...

Page 20: ...20 52 Fig 17 Templates After opening the configuration template a dialog box appears that contains set of camera parameters which can be changed Confirm this dialog by OK button and changes in settin...

Page 21: ...11E 21 52 ks 111e_g_en_100 Fig 18 Modified parameters After applying of configuration template a recapitulation window is shown which contains result of loading and overview of all recently set parame...

Page 22: ...using The whole process of setting the camera lens is realized in following steps Viewing the image from camera on service notebook Taking off the camera cover Camera lens position setup Focusing the...

Page 23: ...nto address field the IP address of camera which will be focused positioned Fig 21 Entering the camera IP address Internet Explorer needs an ActiveX control for its operation If not installed yet you...

Page 24: ...e released Fig 24 The bolts which holds the camera cover Then use a special plastic tool or flat screwdriver for lifting up and releasing the camera cover An appropriate power needs to be applied due...

Page 25: ...red by camera Posi tioning is realized by turning the head with lens while the captured image is viewed over Live View on computer screen Range of positioning is mechani cally limited a bit Fig 27 Cam...

Page 26: ...over back on the cam era Deleting camera from ACM database After completion of procedures of camera configuration and lens adjusting is necessary to delete in ACM Main window records about cameras wit...

Page 27: ...connector wiring Checking of proper wiring of recording unit powering is necessary before first unit switching on For switching the unit off must be essentially used the terminal labelled SB Terminal...

Page 28: ...r forming of service operations takes about 5 minutes pay an appropriate attention to LED indicators Formating disk indicated by blinking LED Scroll Lock Loading of application indicated by alternatin...

Page 29: ...KS 111E 29 52 ks 111e_g_en_100 5 As response to sent request the browser displays a xml file 6 Version number is available between two tags version version Fig 31 Identification of application version...

Page 30: ...KS 111E ks 111e_g_en_100 30 52 5 APPENDIX A Location of components...

Page 31: ...3 KL2 KL2 4 KP2 KP2 5 KCZ1 KCZ1 6 KSP1 KSP1 7 KCZ2 KCZ2 8 KSP2 KSP2 9 KL1 KP1 KL1 KP1 10 KL2 KP2 KL2 KP2 11 KCZ1 KCZ2 KCZ1 KCZ2 12 KSP1 KSP2 KSP1 KSP2 13 KL1 KP1 KL2 KP2 KL1 KP1 KL2 KP2 14 KCZ1 KSP1...

Page 32: ...KS 111E ks 111e_g_en_100 32 52 Fig 33 Scene ID 10 Fig 34 Scene ID 11...

Page 33: ...KS 111E 33 52 ks 111e_g_en_100 Fig 35 Scene ID 12 Fig 36 Scene ID 13...

Page 34: ...KS 111E ks 111e_g_en_100 34 52 Fig 37 Scene ID 14...

Page 35: ...KS 111E 35 52 ks 111e_g_en_100 7 APPENDIX C Block diagram...

Page 36: ...config xml Configuration file KAMERY_200 111e_58_200 cmt Config template Camera KL1 111e_57_200 cmt Config template Camera KP1 111e_62_200 cmt Config template Camera KL2 111e_61_200 cmt Config templat...

Page 37: ...parameters referring to camera adjusting Camera IP Address Location Configuration template KL1 172 16 5 58 ext left cabin A 111e_58_xxx cmt KP1 172 16 5 57 ext right cabin A 111e_57_xxx cmt KL2 172 1...

Page 38: ...KS 111E ks 111e_g_en_100 38 52 9 4 Recording unit Overview of parameters referring to Recording unit adjusting Symbolic name Value PPM_IP 172 16 5 54 PPM_Login service PPM_Password service...

Page 39: ...s Camera Management Main window ACM can be downloaded from Axis company website Direct link to download verified to date 2012 08 23 http www axis com products cam_mgmt_software index htm Download is c...

Page 40: ...52 User name and Password will be used afterwards for accessing cameras there fore they need to be set in accordance with APPENDIX E Configuration pa rameters Login data User name Axis_Login Password...

Page 41: ...y and camera performance The procedures described below assume that we are working with the camera which has its IP address alredy assigned Description of web interface window The web interface window...

Page 42: ...field an IP address of camera web interface of which you want to view Fig 41 Entering of camera IP address Internet Explorer needs an ActiveX control for its operation If not installed yet you will be...

Page 43: ...setting Live View live image from camera Image from camera is displayed after click on Live View item located in web interface Heading Fig 45 Displaying of live image from camera Creating of Server Re...

Page 44: ...nerate the Server Report by click on appropriate button Then it will be available in right Parametrization window part Fig 48 Generating of Server Report Finally new dialog window appears where is sho...

Page 45: ...exception of optionally Ethernet interface By hardware way factory setting of all parameters After resetting is the camera considered as quite new and next steps can be performed in accordance with 4...

Page 46: ...from labels Fig 51 Software way of Restoring the factory setting Restore IP address is retained all another parameters are reseted Default all parameters including IP address are restored After click...

Page 47: ...y setting is recommended Resetting of all parameters including IP address 1 Disconnect the camera network cable 2 Dismount the camera cover To remove the camera cover two bolts which holds the cover m...

Page 48: ...era configuration according to 4 2 Cameras commission ing 11 2 Meaning of camera LED indicators LED Color Description NET Green Connected to 100 Mbit s network Blinking indicates the net work activity...

Page 49: ...p archive with USB flash disc image to local disc of service notebook 2 Copy img2usb exe tool to same directory like USB flash disc image 3 Plug in clear the USB flash disc to the service notebook 4 O...

Page 50: ...KS 111E ks 111e_g_en_100 50 52 Fig 56 Delete partition 6 Confirm partition delete by click Yes Fig 57 Disc management warning 7 Repeat for all USB flash disc partitions...

Page 51: ...n a command prompt as Administrator Navigate to directory with USB flash disc image and img2usb exe tool Fig 59 Directory selection 9 Run img2usb tool img2usb exe usb flash disc file Fig 60 Run img2us...

Page 52: ...rm your selection Fig 62 Disc confirmation 12 Do not make any write operation to created USB flash disc and wait until operation is finished Fig 63 Image writing in progress 13 USB flash disc is ready...