27
MAINTENANCE
(1) Service more frequently when used in dusty areas.
(2) These items should be serviced by an authorized AMICO generator
dealer, unless the owner has the proper tools and is mechanically
proficient. See the AMICO Shop Manual.
(3) For professional commercial use, log hours of operation to determine
proper maintenance intervals.
Periodic maintenance and adjustment is necessary to keep the generator in
good operating condition. Perform the service and inspection at the
intervals shown in the Maintenance schedule below.
Exhaust gas contains poisonous carbon monoxide.
Shut off the engine before performing any maintenance, if the engine
must be run, make sure the area is well ventilated.
WARNING
!
Use only genuine AMICO parts or their equivalent for
maintenance or repair. Replacement parts which are not of equivalent
quality may damage the generator.
NOTICE
MAINTENANCE SCHEDULE
Every 2 years (2)
REGULAR SERVICE PERIOD
Performed at every indicated month or
operating hour interval, whichever
comes first.
ITEM
Engine oil
Check level
Change
Check
Clean
Clean
Check-Clean
Check-Adjust
Clean
Air cleaner
Sediment Cup
Spark plug
Valve clearance
Fuel tank and strainer
Check
(Replaceif
necessary)
Fuelline
Each
use
First
month
or
20 Hrs.
(3)
Every
3 months
or
50 Hrs.
(3)
Every
6 months
or
100 Hrs.
(3)
Every
year
or
300 Hrs.
(3)
(1)
(2)
(2)