15
INSTALLATION
DEFENDI-Burner
The procedure for changing the gas type
Flame
Conversion from LPG
to natural gas
Conversion from natural
gas to LPG
full flame
1.Replace burner nozzle
with the appropriate nozzle
according to the table.
1.Replace burner nozzle
with the appropriate nozzle
according to the table.
2.Gently tighten the adju-
sting screw and check the
flame size.
2.Gently tighten the adju-
sting screw and check the
flame size.
Burner
small flame
hob
oven
full flame
1.Replace burner nozzle with
the appropriate nozzle accor-
ding to the table.
2.Gently tighten the adjusting
screw and adjust the flame.
The temperature in the oven
should be 150
O
C.
1.Replace burner nozzle
with the appropriate nozzle
according to the table.
2.Gently tighten the adju-
sting screw and adjust the
flame. The temperature in
the oven should be 150
O
C.
small flame
In order to perform adjusting operations, take off the knobs. Adjusting elements of the oven
burner are accessible after drawing out the oven chamber floor.
Type of gas
Burner
auxiliary
gas injector
diameter [mm]
medium
gas injector
diameter [mm]
large
gas injector
diameter [mm]
oven
gas injector
diameter [mm]
nominal
thermal power
1,00 kW
nominal
thermal power
1,75 kW
nominal
thermal power
3,00 kW
nominal
thermal power
2,80 kW
G20 2E - 20mbar
G25 2L - 25mbar
0,77
0,97
1,29
1,30
G30 3B/P - 50mbar
0,46
0,60
0,79
0,75
G30 3B/P - 30mbar
0,50
0,65
0,87
0,84