Amiad Water Systems - ADI-X IOM 910101-001180 / 06.2021
60
5
ADI-X Controller Operation
The ADI-X Controller can be operated in four ways:
1.
Hardware interface (ADI-X control panel buttons).
2.
Via ADI-X Desktop Application.
3.
Via ADI-X Mobile Application.
4.
Via ADI-BLE Mobile Application.
This chapter describes the ADI-X controller operation methods.
The following is the instructions for all the applicable controlling methods.
5.1
ADI-X Controller Buttons
There are two main buttons on the ADI-X controller control panel.
Following is the functionality description of the buttons:
Left button
Right button
Short push
Turn on display backlight
Start manual flush
Long push
Enter communication mode
Force full cloud synchronization
5.2
ADI-X Controller Sharing
ADI-X controller can communicate via cloud with one account only. If another account needs access
to the controller via cloud communication, use the share site function. Shared site will be displayed
as "Linked site" in the sites list. Linked account has full access to controller operation but cannot
change the site information and cannot share the site forward (to additional user).
To share the site using
ADI-X Desktop
application:
1.
Sign in to
ADI-X
Desktop application.
2.
Go to "Sites manager" screen in the left menu and choose with site to share.
3.
Click the "Invite" icon on the site you want to share.
Figure 46: ADI-X Desktop application. Sites Manager screen