9
F Install electric system
Connect the power source on the data plate of Motor
Note: 1. For the safety of operators, the power wiring must contact the floor well.
2. Pay attention to the direction of rotations when using three phase motors.
Single phase motor
(See Fig. 12)
1. Connecting the two power supply lines (fire wire
L
and zero wire
N
) to terminals of AC
contactor marked
L1, L2
respectively.
2. Connecting the two motor wires to terminals of AC contactor marked
T1, T2
.
3. Connecting
L2
to
A2
of AC contactor.
4. Two wires of control button connected with terminals of AC contactor marked
A1
,
L1
.
Fig. 12
Single phase
Circuit diagram