15
I. Installing the limit switch control bar and limit switch
(See Fig. 22).
Note: Wire of limit switch should be protected
by protecting plastic hose.
Fig.22
Use 3# Hex wrench loosen
drive rod screw and adjust
the drive rod.
Connecting
wire for
limit switch
54
Limit switch wire
connect
Blue wire connect 11#
terminal, the other end connect
the AC connector A
1
terminal.
Brown wire connect 12#
terminal, the other end connect
4# terminal on the power unit
switch.
Kelly wire connect earth
terminal, the other end connect
earth terminal on the power
unit wire box.