8
D. Install parts of extension columns
(See Fig. 15).
E. Position power-side column
Lay down two columns on the installation site parallelly, position the power-side
column according to the actual installation site. Usually, it is suggested to install
power-side column on the front-right side of the direction which vehicles are driven to
the lift. This lift is designed with 2-Section columns. Adjust the height according to the
ceiling height and connect the inner and extension columns.
OH-9, : Not suitable for installation when the height of the workshop is less than
143-3/4"; only low setting installation for height between 143-3/4" - 151-1/2 "; the
height of the workshop is greater than 151-1/2", installation can be in both high and
low setting;
Fig. 15
25A
69
69A
84
25
23
27