AMG AMG3603B5E-DR-SF Instruction Manual Download Page 8

AMG Systems Ltd. reserves the right to make changes to this 
document without notice. The information herein is believed to 
be accurate. No responsibility is assumed by AMG for its use.  

Page 8 of 16 

AMG3608BERN-DR-SF Instruction 
Sheet D18195-02.doc 
 

 

 

Bank B Data 

Data Bank B channels are operational when fitted with appropriate daughter boards. 
 

 

Data Interface Daughter Board Options 

The data interface daughter board options are as follows: 
 

Option Code 

'x'

 

Part No.

 

Description

 

X12542 

4 Wire Audio Interface Daughter Board 

X04057 

RS422/485 Data Interface Daughter Board 

X04049 

RS232 Data Interface Daughter Board 

X04058 

20mA Current Loop Data Interface Daughter Board 

X12579 

TTL Data Interface Daughter Board 

X12578 

Contact Closure Data Interface Daughter Board 

X13038 

FTT10A Echelon Lonworks Data Interface Daughter Board 

 

 

Data and Audio Channel Configuration 

The data expansion board slots are accessed by removing the AMG unit from its case. A data channel 
is active when a daughter board is installed in the required data channel slot. Each data interface 
board enables one bi-directional channel.  
 

 

Daughter Board Layout 

The channel slots are as follows: 
 

 

 

 

Data and Audio Daughter Board Fitting Instruction 

The data and audio daughter boards pushed on to the pin headers mounted on the data expansion 
boards. Ensure that the connectors are lined up correctly and not offset before pushing firmly in place. 
Note that the data and audio channel numbers are associated with each slot. This allocates the pin 
numbers on the rear panel connector together with the front panel LED indicators. 
 

 

Summary of Contents for AMG3603B5E-DR-SF

Page 1: ...sure channels and provide full duplex 100BaseT Ethernet connectivity with up to 8 AMG3603B5E DR SF or AMG3603B5ER DR SF rackmount equivalent insert units over a dual redundant multimode optical fibre...

Page 2: ...nfiguration 7 Data and Audio Channel Configuration 7 Data Channel A Configuration 7 Data Interface Connections Channel A 7 Bank B Data 8 Data Interface Daughter Board Options 8 Data and Audio Channel...

Page 3: ...ke changes to this document without notice The information herein is believed to be accurate No responsibility is assumed by AMG for its use Page 3 of 16 AMG3608BERN DR SF Instruction Sheet D18195 02...

Page 4: ...onto the outgoing optical signal As each unit regenerates the optical signal the optical dynamic range between each optically connected node is 17dB Data Channel Configuration At the AMG3603B5E DR SF...

Page 5: ...system single channel data insert units can be combined to make an 8 channel data transmission system as illustrated below If a fibre link is broken operation of the ring continues by making use of t...

Page 6: ...cases the units will operate successfully over longer fibre lengths It is advisable however for distances greater than 500m to have the optical fibre tested Power Connection Power supply from plug in...

Page 7: ...by monitoring the differential voltage level across the input A differential level below 600mV positive or negative will be detected as a tri state condition A level above 600mV positive or negative w...

Page 8: ...e Daughter Board 5 X12578 Contact Closure Data Interface Daughter Board 6 X13038 FTT10A Echelon Lonworks Data Interface Daughter Board Data and Audio Channel Configuration The data expansion board slo...

Page 9: ...e as follows Pin No Description Bank Pin No Description Bank 1 CH1 IN A B 20 CH1 OUT A B 2 CH1 IN B B 21 CH1 OUT B B 3 CH2 IN A B 22 CH2 OUT A B 4 CH2 IN B B 23 CH2 OUT B B 5 CH3 IN A B 24 CH3 OUT A B...

Page 10: ...Channel A Data Present TX RS485 or RS422 Green logic zero V V present on IN IN Red logic one V V present on IN IN Off tri state off or no connection on IN IN Data Present TX RS232 Green logic zero V p...

Page 11: ...t s when Ethernet only or 50MBit s when the low speed data option is also used If one node is transmitting the entire bandwidth is available for this traffic If multiple nodes transmit simultaneously...

Page 12: ...each Rx or Tx RS 232 or RS 485 on Management Port Multiple Rx Tx units use RS 485 and effectively parallel all the RS 485 ports together Connect to PC RS 232 Port via RS 485 RS 232 convertor Propriet...

Page 13: ...s it is recommended that the RS 485 interface is used with each RS 485 pair connected in parallel In this case an RS 485 to RS 232 USB converter is required in order to connect to a standard PC Comms...

Page 14: ...ange from this recorded state A change of state would be Addition or loss of video at any insert node Addition or loss of primary optical input at any node Addition or loss of secondary optical input...

Page 15: ...ot snag or get trapped To replace the PCB s into the case slide the PCB s gently into the case aligning the boards with the appropriate slots Ensure that the fibre do not snag or get trapped Safety AM...

Page 16: ...ake changes to this document without notice The information herein is believed to be accurate No responsibility is assumed by AMG for its use Page 16 of 16 AMG3608BERN DR SF Instruction Sheet D18195 0...