AMG3608BERN-DR-SF Instruction
Sheet D18195-02.doc
Connections
Optical Connections
PRIMARY OPTO OUT
Connector ............................................ LC/PC
Primary Optical Launch Power ............ -5dBm
Wavelength .......................................... 1550nm
Secondary Optical Sensitivity .............. -22dBm
Wavelength .......................................... 1310nm
PRIMARY OPTO IN
Connector ............................................ LC/PC
Primary Optical Sensitivity ................... -22dBm
Wavelength .......................................... 1550nm
Secondary Optical Launch Power ....... -5dBm
Wavelength .......................................... 1310nm
Optical Fibre ........................................ Multimode 50/125 or 62.5/125**
**Note: the transmission distance is limited by the bandwidth of the Multimode optical fibre. The optical
data rate is 1.25Gbits/s. The maximum bandwidth specification at this data rate for Multimode fibre is
500m, although in most cases the units will operate successfully over longer fibre lengths. It is
advisable however for distances greater than 500m, to have the optical fibre tested.
Power Connection
Power supply ....................................... from plug in connection on the AMG2009 / AMG2015 subrack
Power consumption ............................. 15 Watts max.
Data and Audio Channel Connections
DATA CHANNEL A
Data Channel A ................................... 1 channel
Data Connector .................................... RJ45
Channel A Interface
On Board Data Interface
– RS232, RS422 or RS485. Selected by slide switch
below RJ45 connector.
RS232
– switch position - high (closest to BNC connections)
RS422
– switch position – middle
RS485
– switch position – low (furthest from BNC connections)
DATA BANK B
Data/Audio Channels
– BANK A ......... Not Used
Data/Audio Channels
– BANK B ......... 8 Contact Closure channels
Connector ............................................ 37-way D-Type female connector - shielded.
Connections ......................................... See appropriate section for connection and configuration details
Ethernet Connection
Ethernet Data Connector .................... RJ45
Interface ............................................... Auto-negotiation up to 100BASE-TX full duplex
Ethernet Data Rate .............................. Maximum 50Mbits/s total Ethernet traffic on fibre