BEDIENUNGSANLEITUNG / INSTRUCTION MANUAL AMC60
59
SYSTEM SET UP
When you start a charge process, the integral safety time automatically starts
running at the same time. This is programmed to prevent overcharge the
battery if it proves to be faulty, or if the termination circuit cannot detect the
battery full. The value for the safety time should be generous enough to allow a
full charge of the battery.
Safe time Calculation
When charging NiMH or NiCd batteries, divide the capacity by current, then
divide the result by 11.9, set this number as the value for safety time setting. If
the charger stopped at this threshold, about 140% of the capacity will have
been fed into the battery.
This program sets the maximum charge capacity that will be supplied to the
battery during charge. If the delta pack voltage is not detected nor the safety
time expired by any reason, this feature will automatically stop the process at
the selected capacity value.
The internal chemical reaction of the battery causes the temperature of the
battery to rise. When the temperature limit is reached, the process is
terminated.
You can choose whether to display the temperature in Celsius or Fahrenheit.
Safety Timer
ON 120Min
Capacity Cut-off
ON 5000mAh
Temp Cut-OFF
ON 50°C/122°F
Temperature unit
Celsius
Capacity
Current
Safety Time
2000mAh
2,0A
(2000/2,0 = 1000) / 11,9 = 84 Minutes
3300mAh
3,0A
(3000/3,0 = 1100) / 11,9 = 92 Minutes
1000mAh
1,2A
(1000/1,2 = 833) / 11,9 = 70 Minutes