Securing the fixture in drywall

Securing fixture to ceiling tile

Semi-recessed fixtures shown without thermal protectors

Warning

:  Before starting any work ensure 

that all sources of power are turned off.  All 

work must meet local/national codes and be 

performed by a certified electrician.  

Do not

 

mount fixtures vertically. 

Installation Instructions

Vault w/ visor

C-Scroll w/ visor

Roundel w/ visor

These installation instructions are valid with the above Ametrix styles.

2.

3.

Sheet 2 of 4

Small, INDOOR

SRI 

(S

emi-

R

ecessed

, I

ntegral ballast

)

Visor and Non-Visor

ADY071458   REV A (ECN070344)

3.

2.

Fixture
assembly

Ceiling tile

Universal
bracket

#10-32 x3/8"
Pan head screw
(4x)

1.

  If possible, remove ceiling tile from grid to facilitate fixture 

     installation.

2.

  Using cut out dimensions provided on page four(4), cut 

     appropriate size opening in ceiling tile.

3.

  Insert fixture assembly into cut out in ceiling tile.

1.  

Using cut out dimensions provided on page four(4), cut 

     hole into dry wall and feed power wire to hole.

2.

  After removing fixture head, loosen #10-32 x3/8" Pan head 

     screws and remove cover plate closest to power feed.

3.

  Knock out appropriate hole for conduit and attach as shown 

     on page three(3).

4.

  Replace cover plate and secure with #10-32 x3/8" Pan head 

     screws and press fixture housing into hole in drywall.

Wiring the fixture

(drywall)

Cover plate

Conduit from
power source.
(by others)

Fixture housing

#10-32 x3/8"
Pan head screws
(2x)

#10-32 x 3/8"
Pan head screws
(4x)

Universal brackets
(2x)

Replacing brackets on fixture housing

  

(ceiling grid)

1.

  Loosely reattach brackets to both sides of fixture housing.

2.

  Press brackets flush to ceiling tile and secure using #10-32 x 

     3/8".

1.

  Prior to pushing fixture into hole in drywall, tie off fixture 

     housing to structure using saftey wire(by others) as show on 
     page three(3).

2.

  Gently push fixture housing into hole and tighten 1/4-20 x 1 

     1/2" Pan head screw from inside fixture housing to tighten 
     drywall bracket around drywall.

3.

  Connect appropriate wires from fixture head and ensure all 

     wires are properly matched.

4.

  Replace fixture head assembly on keyhole screws and 

     tighten.