Page 3
Installation Guide
NIR Thermal Imager
2 Specifications
2.1 Configurations
Temperature Range
Model Reference NIR
8 mm lens*
25 mm lens
50 mm lens
75 mm lens
600 to 1000 °C / 1112 to 1832 °F
10 - 08
10-25
10-50
10-75
800 to 1400 °C / 1472 to 2552 °F
14 - 08
14-25
4-50
14-75
1000 to 1800 °C / 1832 to 3272 °F
18 - 08
18-25
18-50
18-75
1400 to 3000 °C / 2552 to 5432 °F
-
30-25
30-50
30-75
2.2 Optical Performance
Lens Type
8 mm lens
25 mm lens
50 mm lens
75 mm lens
Field of View (Horiz x Vert)
44° x 33°
14.4° x 10.8°
7.2° x 5.4°
4.8° x 3.6°
Focus Range
600 mm (2 ft) to infinity (manual focus)
IFOV
1.2 mrad
0.40 mrad
0.20 mrad
0.13 mrad
Window Material
Glass
Glass
Glass
Glass
2.3 Close-up Lenses
Close-up Lens Ref:
G1
G2
G3
G4
G5
Focal Range ( mm)
100 to 123 120 to 160 150 to 215 200 to 340 250 to 495
Focal Range (inches)
4 to 4.85
4.7 to 6.3
5.9 to 8.5 7.8 to 13.4 9.8 to 19.5
2.4 Imager Performance
System Temperature Accuracy
0.5 % (K) up to 1600 °C / 2912 °F and 1% (K) above
Spectral Range
780 to 1100 nm
Detector
Silicon focal plane array
Detector Array Format
656 x 494
Frame/Frequency
30 Hz (Gigabit Ethernet)
Operating Temperature Range
0 to 50 °C / 32 to 122 °F (non-condensing)
Storage Temperature Range
-20 to 80 °C / -4 to 176 °F (non-condensing)
Operating Humidity
0 to 90 % non-condensing
Sealing
IP65 / NEMA 4 (with Phoenix Ethernet connector)
Vibration
3 g between 10 and 300 Hz
NIR Interfaces
Separate sockets / lead for power and data connection
Power Range
12 to 30 V dc, 3 Watts
Data Out
Digital data over Gigabit Ethernet (RJ-45)
Mountings
Two ¼ in BSW mounting holes spaced 25 mm apart allow it be
mounted to a large range of accessories
Software
Complete LIPS (Land Image Processing Software) package for
PC
Standard Accessories
Power Supply, Cables, Software, Close-up Lenses
*8 mm lens requires hot target to fill minimum of 30% of scene to achieve stated accuracy