Ametek Land Landcal P80P User Manual Download Page 3

Contact Us

UK - Dronfield

Land Instruments International
Tel: +44 (0) 1246 417691
E-Mail: [email protected]
Web: www.landinst.com

USA - Pittsburgh

AMETEK Land, Inc.
Tel: +1 412 826 4444
E-Mail: [email protected]
Web: www.ametek-land.com

For further details on all LAND/Ametek offices, distributors and representatives, please visit 

our websites.

Return of Damaged Goods

IMPORTANT  If any item has been damaged in transit, this should be reported to the carrier and to the 

supplier immediately.  Damage caused in transit is the responsibility of the carrier not the supplier.

DO NOT RETURN a damaged instrument to the sender as the carrier will not then consider a claim.  Save 

the packing with the damaged article for inspection by the carrier.

Return of Goods for Repair

If you need to return goods for repair please contact our Customer Service Department.  They will be 

able to advise you on the correct returns procedure.

Any item returned to Land Instruments International should be adequately packaged to prevent damage 

during  transit.

You must include a written report of the problem together with your own name and contact information, 

address, telephone number, email address etc.

Design and Manufacturing Standards

The Quality Management System of Land Instruments International is approved to BS EN ISO 9001 for 

the design, manufacture and on-site servicing of combustion, environmental monitoring and non-contact 

temperature measuring instrumentation.  

Approvals apply in the USA

This instrument complies with current European directives relating to Electromagnetic 

Compatibility 89/336/EEC and Low Voltage Directive 73/23/EEC.

Operation of radio transmitters, telephones or other electrical/electronic devices in close proximity 

to the equipment while the enclosure doors of the instrument or its peripherals are open, may cause 

interference and possible failure where the radiated emissions exceed the EMC directive.

The protection provided by both CE and IP classifications to this product may be invalidated if alterations 

or additions are made to the structural, electrical, mechanical or pneumatic parts of this system. Such 

changes may also invalidate the standard terms of warranty.

Copyright

This manual is provided as an aid to owners of Land Instruments International’s products and contains 

information proprietary to Land Instruments International.  This manual may not, in whole or part, be 

copied, or reproduced without the expressed written consent of Land Instruments International Ltd.

Copyright © 2012 Land Instruments International.

Summary of Contents for Land Landcal P80P

Page 1: ...Landcal P80P Calibration Source Land Instruments International 2012 User Guide Issue 6 September 2012 Publication N 198 031 Language English...

Page 2: ...n It is possible that this equipment is to be installed on or near to machinery or equipment operating at high temperatures and high pressures Suitable protective clothing along with face and eye prot...

Page 3: ...s etc Design and Manufacturing Standards The Quality Management System of Land Instruments International is approved to BS EN ISO 9001 for the design manufacture and on site servicing of combustion en...

Page 4: ......

Page 5: ...or Platinum resistance thermometer if supplied 7 6 3 Operation of the source at below ambient temperature 7 7 Calibration of Radiation Thermometers 8 7 1 Preparation 8 7 2 Thermometer calibration 8 7...

Page 6: ...Landcal P80P Calibration Source User Guide...

Page 7: ...he source can be supplied The relationship between the indicated temperature on the controller and the radiance temperature as measured by a secondary standard radiation thermometer is reported 2 The...

Page 8: ...hock never expose the elements terminals or other electrical components when the calibration source is connected to the mains supply After completion of a repair replace all safety plates before switc...

Page 9: ...increase the emissivity value The cavity is heated or cooled using Peltier elements The temperature is controlled by a platinum resistance thermometer connected to a 3 term digital controller having...

Page 10: ...g Design 120 cone Inner diameter 50mm 2 0in Internal length 155mm 6 1in Emissivity 0 995 Controller input Resistance thermometer Controller type Eurotherm 3216 with RS 232 serial interface Electrical...

Page 11: ...ule The colour code for the cable is Brown lead Live Blue lead Neutral Green Yellow lead Earth The source may be connected directly to a 5 amp fused plug and socket The wiring diagram of the P80P is g...

Page 12: ...d at any temperature in the range 10 C 15 F to 80 C 175 F Set the controller to the required value as follows 1 When the source is switched on the fluorescent indicator panel displays the measured val...

Page 13: ...hould not be used as an accurate measurement of target cavity temperature 6 3 Operation of the source at below ambient temperature The LANDCAL Blackbody Source type P80P uses Peltier modules to cool t...

Page 14: ...istance between target and thermometer By adjusting the vertical and transverse vernier screws confirm that the holder is sighted correctly 7 2 Thermometer calibration When soaked conditions have been...

Page 15: ...used in conjunction with an indicator have a resolution of 1K 2 F Fixed installation thermometers whose output is measured on a digital voltmeter will have a resolution of between 0 1K 0 2 F and 0 5K...

Page 16: ...the LAND distributors for repair 8 2 Certification To continue to carry out calibration checks which are traceable to National Standards it will be necessary to obtain a Certificate of Calibration De...

Page 17: ...e of operation When in Level 2 the parameter lists within the controller can be displayed The Scroll key allows access to the adjustable parameters within the controller Most lists and parameters are...

Page 18: ...ns to the measured temperature when no key is pressed for 0 5 seconds 9 3 Altering the Ramp Rate 1 Press the Scroll key until SP RAT SetPoint ramp rate is displayed 2 Use the Down or Up key to adjust...

Page 19: ...ring the Communication Address 1 Press the scroll key until Addr address is displayed 2 To alter the value press the Down or Up key The display returns to the measured temperature when no key is press...

Page 20: ...Page 14 Landcal P80P Calibration Source User Guide 10 Spares No spare parts are available for this instrument Contact LAND if you have a specific requirement...

Page 21: ...ration Accessory enables simple line up of Land fixed installation radiation thermometers When the source is stood on the optional carrying case the bench to mid tar get dimension equals that of the o...

Page 22: ...Page 16 Landcal P80P Calibration Source User Guide...

Page 23: ...rs accessories and mountings and special instruments based on UNO Application dedicated processors based on LANDMARK Graphic ABTS S and ABTS U FTS VDT S and VDT U DTT FLT5 A This 36 month warranty is...

Page 24: ...onditions outside the Ambient Temperature Humidity and Vibration rating of the product environmental contamination solvent vapours deposition of airborne contamination cooling liquids of non neutral p...

Reviews: