
Installation
17
2.8 Calibration
The Intellipoint™ model RNT (Standard Sensitivity) and
RHT (High Sensitivity) feature Auto-Cal calibration. Auto-
Calibration is suitable for liquid and slurry applications. For
applications such as granular materials, interface measurement
of two liquids, and plugged chute installations, a Manual
Calibration IntelliPoint is recommended.
If you purchased an Auto-Cal Intellipoint and have determined
that you require a Manual Calibration Intellipoint based on the
Application Guide, please contact our field service department
at 215-674-1234.
2.8.1
Using the Intellipoint with Auto-Calibration
After the Intellipoint is installed in the vessel with material
below the sensing element, simply apply power. The Intellipoint
electronic unit will auto calibrate.
Caution – The material being measured must be below the
sensing element when power is applied (Sensing element
uncovered).
Calibration is complete.
If power has been applied to the IntelliPoint prior to installation
(on a test bench) or, if the Intellipoint is moved from one vessel
to another, RECAL is necessary for the unit to capture the new
air value.
After the IntelliPoint has been installed with the measured
material below the sensing element, press and hold the "ReCal"
button (shown in
Figure 2-4
) for five (5) seconds. After five
seconds, the two LED’s flash for sixty seconds before reset
occurs.
Summary of Contents for IntelliPoint RF RNT Series
Page 4: ...Contents ...
Page 6: ...Section 1 ...
Page 37: ...Troubleshooting 31 Section 5 ...
Page 41: ...Control Drawings 35 6 1 FM FMc Control Drawings Continued ...
Page 42: ...RNTXX IntelliPoint RF Series User s Manual 36 6 1 FM FMc Control Drawings Continued ...
Page 43: ...Control Drawings 37 6 1 FM FMc Control Drawings Continued ...
Page 44: ...RNTXX IntelliPoint RF Series User s Manual 38 6 1 FM FMc Control Drawings Continued ...
Page 45: ...Control Drawings 39 6 1 FM FMc Control Drawings Continued ...
Page 46: ...RNTXX IntelliPoint RF Series User s Manual 40 6 1 FM FMc Control Drawings Continued ...
Page 51: ...Control Drawings 45 6 1 FM FMc Control Drawings Continued ...
Page 52: ...RNTXX IntelliPoint RF Series User s Manual 46 6 1 FM FMc Control Drawings Continued ...
Page 56: ...RNTXX IntelliPoint RF Series User s Manual 50 6 2 ATEX Control Drawings ...
Page 57: ...Control Drawings 51 6 2 ATEX Control Drawings Continued ...
Page 66: ...RNTXX IntelliPoint RF Series User s Manual 60 6 4 IECEx Control Drawings ...
Page 67: ...Control Drawings 61 6 4 IECEx Control Drawings Continued ...
Page 75: ...Control Drawings 69 6 5 Mounting and Wiring for Spark Protector Drawings ...
Page 77: ...Control Drawings 71 6 5 Mounting and Wiring for Spark Protector Continued ...
Page 78: ...RNTXX IntelliPoint RF Series User s Manual 72 6 6 Adding a Padded Capacitor ...
Page 79: ...Control Drawings 73 6 6 Adding a Padded Capacitor Continued ...
Page 80: ...RNTXX IntelliPoint RF Series User s Manual 74 6 6 Adding a Padded Capacitor Continued ...
Page 81: ...Control Drawings 75 6 7 Dual Seal Assembly for 700 Series Sensing Elements ...
Page 82: ...RNTXX IntelliPoint RF Series User s Manual 76 6 7 Dual Seal Assembly Continued ...
Page 83: ...Control Drawings 77 6 7 Dual Seal Assembly Continued ...
Page 84: ...Appendix A ...