5.1 Testing Sensing Element
To test the sensing element, disconnect the integral cable.
Refer to
Figure 5.1
.
Figure 5.1
Testing Sensing Element
Expect the following measurements:
Center Wire
Shield
Ground
Three Terminal Probes without Shield Tab
Measured Resistance (Sensor dry and clean):
Center Wire - Shield
Center Wire - Ground
∞
Ohms
Shield - Ground
Resistance readings must be taken
using an analog ohmeter set to Rx1000 scale.
∞
Ohms
∞
Ohms
When tank level is known to be below the
sensor, minimum acceptable values are:
CW-G 1000 ohms.
CW-S 600 ohms.
S-G
300 ohms.
If the readings are less than the minimum
acceptable values:
1. Check to see if tank is full, or if a severe
coating is present.
2. Clean sensor and re-measure the sensor
resistances.
Note: Low resistance readings are acceptable
if the sensor is covered with a conductive
liquid. Also, low resistance readings can be
the result of material lodging in a long
mounting nozzle. Refer to Figure 2-2.
Note: A reading of zero ohms usually
indicates a metal-to-metal short circuit. Check
for contact with tank wall, mounting nozzle, or
other tank structure.
integral
cable
Summary of Contents for IntelliPoint RF RGL Series
Page 4: ......
Page 6: ...Contents...
Page 8: ...Section 1...
Page 22: ...Section 3...
Page 30: ...Section 5...
Page 38: ...Section 7...
Page 40: ...IntelliPoint RF RML Series Control Drawings 32 7 1 FM Control Drawings Continued...
Page 41: ...33 IntelliPoint RF RML Series Control Drawings 7 1 FM Control Drawings Continued...
Page 42: ...IntelliPoint RF RML Series Control Drawings 34 7 1 FM Control Drawings Continued...
Page 43: ...35 IntelliPoint RF RML Series Control Drawings 7 1 FM Control Drawings Continued...
Page 44: ...IntelliPoint RF RML Series Control Drawings 36 7 1 FM Control Drawings Continued...
Page 45: ...37 IntelliPoint RF RML Series Control Drawings 7 1 FM Control Drawings Continued...
Page 46: ...IntelliPoint RF RML Series Control Drawings 38 7 1 FM Control Drawings Continued...
Page 47: ...39 IntelliPoint RF RML Series Control Drawings 7 1 FM Control Drawings Continued...
Page 48: ...IntelliPoint RF RML Series Control Drawings 40 7 1 FM Control Drawings Continued...
Page 49: ...41 IntelliPoint RF RML Series Control Drawings 7 1 FM Control Drawings Continued...
Page 53: ...45 IntelliPoint RF RML Series Control Drawings 7 3 Adding a Padded Capacitor...
Page 54: ...IntelliPoint RF RML Series Control Drawings 46 7 3 Adding a Padded Capacitor Continued...
Page 55: ...47 IntelliPoint RF RML Series Control Drawings 7 3 Adding a Padded Capacitor Continued...
Page 56: ...Appendix A...
Page 59: ......