7
1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • Phone 248.435.0700 • Fax 248.435.8120 • www.ametekapt.com
AUTOMATION & PROCESS TECHNOLOGIES
®
Figure 2-2: Mounting LDT in a Hydraulic Cylinder
Figure 2-3: Port Detail (SAE J1926/1)
A
.004 A
.008 A
125
125
PITC H
DIA.
REF.
S EE N O TE 4
.094 MAX.
R.015
MAX.
.008
.004
R
RECOMMENDE D
MIN. SPOTFAC E
DIAMETER
SEE NOTE 1
1.18
.500
.866
.813
+/-.002
45°
15°
.106
+/-.008
1.250
SEE NOTE 3
SEE NOTE 4
3/4-16 UNF-2B THREAD
1.100
SEE NOTE 4
MINIMU M
SEE NOTE 2
NOTES:
1. IF FACE OF PORT IS ON A
MACHINED SURFACE,
DIMENSIONS 1.180 AND .094
NEED NOT APPLY AS LONG
AS R.008/.0004 IS
MAINTAINED TO AVOID
DAMAGE TO THE O-RING
DURING ASSEMBLY.
2. MEASURE PERPENDICU-
LARITY TO A AT THIS
DIAMETER.
3. THIS DIMENSION APPLIES
WHEN TAP DRILL CANNOT
PASS THROUGH ENTIRE
BOSS.
4. THIS DIMENSION DOES
NOT CONFORM TO SAE
J1926-1.
O PTI O NAL R O D B US HIN G
MAGNET SPACER
O-RING SEAL
S TANDARD 4-H O LE MA G NET
0.5” BORE MINIMUM