Page 1: ...LINEAR DISPLACEMENT TRANSDUCERS 953A VMAX Linear Displacement Transducer Series 956 ABSOLUTE PROCESS CONTROL KNOW WHERE YOU ARE REGARDLESS INSTALLATION MANUAL Series 953...
Page 2: ...ghly accurate continuous machine positioning in a variety of industrial applications This sensor is built to withstand the most severe environmental conditions and is completely absolute This means th...
Page 3: ...3 1080 N Crooks Road Clawson MI 48017 800 635 0289 Phone 248 435 0700 Fax 248 435 8120 www ametekapt com AUTOMATION PROCESS TECHNOLOGIES Figure 1 1 953A Dimension Drawing...
Page 4: ...the Magnet Assembly Installing Support Brackets It is recommended that a support bracket be used Chapter 2 Installing the LDT with LDTs having a rod 30 71 in length Supporting the end of the rod will...
Page 5: ...2 1 A non ferrous spacer must be used to separate the magnet assembly from the head of the piston rod See Figure 2 2 The magnet should not be closer than 2 0 from the base of the LDT s hex head when...
Page 6: ...rrous spacer against the piston face followed by the magnet and then the chamfered rod bushing if the LDT s rod is 60 0 or longer in length 3 Insert non ferrous screws through the chamfered rod bushin...
Page 7: ...500 866 813 002 45 15 106 008 1 250 SEE NOTE 3 SEE NOTE 4 3 4 16 UNF 2B THREAD 1 100 SEE NOTE 4 MINIMUM SEE NOTE 2 NOTES 1 IF FACE OF PORT IS ON A MACHINED SURFACE DIMENSIONS 1 180 AND 094 NEED NOT A...
Page 8: ...nnected to earth ground and should be used for connection to interface devices only For assistance refer to your LDT s wiring drawing in this chapter In order for the VMAX to operate properly the exte...
Page 9: ...g the Differential method the electrical noise and voltage offset errors produced by the currents running through the Power Supply Common are eliminated The Power Supply Common and Analog Common are i...
Page 10: ...hone 248 435 0700 Fax 248 435 8120 www ametekapt com AUTOMATION PROCESS TECHNOLOGIES AUTOMATION PROCESS TECHNOLOGIES Figure 3 4 Wiring for Connector Option C Integral Cable Assembly Figure 3 5 Wiring...
Page 11: ...ESS TECHNOLOGIES Figure 3 7 Wiring for Connector Option B 8 Pin DIN Voltage Output CAUTION Pinout is different for voltage vs current models with connector option B Cable SD0553300LXX NOTE XX Length i...
Page 12: ...com AUTOMATION PROCESS TECHNOLOGIES Figure 3 9 Wiring for Connector Option M 6 Pin DIN AUTOMATION PROCESS TECHNOLOGIES Cable SD0553200LXX NOTE XX Length in feet AUTOMATION PROCESS TECHNOLOGIES Figure...
Page 13: ...Power Supply Common for 4 seconds Remove the short for 1 second Within 5 seconds short the Programming Input pin to the Power Supply VDC This completes the programming process 3 3 Features Automatic...
Page 14: ...ated but within the active region of the probe 6 Push the black Zero button for 4 seconds release for 1 second Within 5 seconds push the Span button NOTE This time the Span button is pushed for the fi...
Page 15: ...etween pins 7 Reconnect the mating connector to the LDT 953A 0120 V0 X Stroke Length Insert stroke length to 0 1 inch Enter as a four place number Example A 12 0 stroke enters as 0120 OR Insert stroke...
Page 16: ...ested IEC 60068 2 27 30Gs lab tested IEC 60068 2 6 Zero Span Adjustability Factory set at Null Zone Dead Band locations Field re settable at any location within active stroke Approvals CE 89 336 EEC E...
Page 17: ...NOTES Part Number Serial Number Purchase Order Number Sales Order Number Comments...
Page 18: ...97 Phone 248 435 0700 Toll Free 800 635 0289 Fax 248 435 8120 www ametekapt com 953A M3R 4 12 Z191 AUTOMATION PROCESS TECHNOLOGIES Copyright 2012 by AMETEK Automation Process Technologies All Rights R...