3.8
REMOTE OVERVOLTAGE SETPOINT
CAUTION!
Do not program the remote overvoltage set point greater than 10% (5.5V)
above the power supply rated voltage (except as noted) as internal power
supply damage may occur.
A remote DC voltage source can be connected externally between
terminals J1-6 (COM) and J1-3 (REM OV SET) to set the output
overvoltage trip level. A 0.25-5.5 VDC signal equals 5-110% of rated
output voltage. See Figure 3-18 for connection requirements.
+
-
1
13
COM 6
REM OV SET 3
0-5.5 VDC
VOLTAGE
SOURCE
Figure 3-18. Remote Overvoltage Set Using DC Voltage Source
Note:
The Remote OVP trip level will ALWAYS take precedence over the
local trip level, even if the local OVP trip level is set to a lower value. To
reset an OVP externally, apply a 10.5–13.3 VDC signal to J1-3 for a
minimum of four (4) seconds.
Summary of Contents for AMREL SPS-A Series
Page 2: ......
Page 3: ......
Page 4: ......
Page 6: ...ii This page intentionally left blank ...
Page 8: ...iv This page intentionally left blank ...
Page 10: ...vi This page intentionally left blank ...
Page 16: ...CONTENTS AMREL SPS A Series vi M550129 01 Rev A This page intentionally left blank ...
Page 22: ...Overview AMREL SPS A Series 1 6 M550129 01 Rev A This page intentionally left blank ...
Page 42: ......
Page 71: ...AMREL SPS A Series Operation M550129 01 Rev A 3 29 This page intentionally left blank ...
Page 72: ......
Page 76: ...Maintenance AMREL SPS A Series 4 4 M550129 01 Rev A This page intentionally left blank ...