TROUBLESHOOTING
March 31, 2005 10-3
SYMPTOM
PROBABLE CAUSES
Low Number Of
A.H.’s Returned
To Battery
(1) Faulty Lift Interrupt
(2) Battery Not Fully Discharged
(3) Manual Disconnect
(4) Rates Set Incorrectly
(5) Fixed Temperature Set Incorrectly
(6) Charge Curve Incorrect
(7) Battery Not Providing Nameplate Rating
(8) Bad Control Board
(9) Bad BID
33
39
34
29
30
28
26
7
32
Battery
Temperature Too
High
(1) Insufficient Cool Down Before And/Or After Charging
(2) Battery Power Demand Too Great
(3) Rates Set Incorrectly
(4) Fixed Temperature Set Incorrectly
(5) Charge Curve Incorrect
(6) Equalize Schedule
(7) Control Set For Voltage/Time
(8) Control Set For Cell Forming
(9) Bad BID
40
41
29
30
28
27
38
36
32
Incorrect
Charge Rate
(1) Rates Set Incorrectly
(2) Fixed Temperature Set Incorrectly
(3) Charge Curve Incorrect
(4) Battery A.H. Not Equal To Charger A.H.
(5) Battery Has Incorrect Size BID
(6) Bad Control Board
(7) BID not Programmed Properly
29
30
28
33
32
7
32
Long CDAC
Approval Delay
(1) Bad CDAC Cabling
(2) CDAC System Down (Computer)
(3) No AC To Control Of 1 Or More Chargers
(4) No CDAC System And Charger I.D. In Control isn’t set to “0000”
(5) Bad Expansion Board
(6) Bad Control Board
42
43
44
45
24
7
ACTION
STEPS
Summary of Contents for ULTRA CHARGE
Page 17: ...6 4 March 31 2005 193111 068 OPERATION ULTRA CHARGE RECHARGING CAPABILITY Figure 6 1 ...
Page 29: ...193111 068 UC2000 CONTROL FEATURES 7 12 Revised October 31 2005 Figure 7 2 ...
Page 37: ...193111 068 PROGRAMMING YOUR UC2000 CONTROL 8 8 Revised August 30 2005 Figure 8 1 ...
Page 63: ......
Page 64: ......
Page 65: ......
Page 66: ......
Page 67: ......
Page 68: ......
Page 69: ......