Timer Start Mode Programming Your
UC2000 Control
The Timer Start Mode Feature of the UC2000 Control
allows the user the override the automatic start/stop
features of the control and manually select the desired
charge time. This can be useful for charging batteries
in a maintenance shop, or for extended equalize charg-
ing of batteries with severely mismatched cells.
The Timer Start Mode can be programmed in the
Program Menu at Start Mode (function #30). With the
Timer Start Mode selected the charger will display
CHG CYCLE TIME when a battery is connected.
Charge times from 0 hours, 1 minute, to 23 hours, 59
minutes can be entered. Pressing the Enter key will
start the charge. The charger will then charge the con-
nected battery based on the any parameters that have
been programmed into the control. For example,
con-
stant current charging
can be achieved utilizing the
custom curve programming in conjunction with the
Timer Start Mode. Listed to the right is an example of
programming an Ultra Charge to constant current
charge a battery for 20 hours at a 5 amp/100AH rate.
Application
24-Cell 935AH Battery
1050T3-24 Ultra Charge
When programmed and connected as shown to the
right, the charger will charge the battery at 48 amps for
20 hours before automatically shutting off.
It should be noted that any programming that is done to
set up a special charge (such as Timer Start Mode,
Custom Curve, etc.) must be reset to allow resumption
of normal charging.
On battery connection, the control will ask for the cycle
charging time to be entered. Key in 20 hours and
press the “enter” key.
193111-068
PROGRAMMING YOUR UC2000 CONTROL
Revised October 31, 2005 8-7
Key Entry
Display
ULTRA CHARGE
Program Review
Menu Tree 1 – 4
2
Present Time 12:34
30
Start Mode Auto
Enter
Start Mode Auto
▲▲▲▲
Start Mode Timer
Enter
Start Mode Timer
36
Fixed Amp Hrs. 1050
Enter
Fixed Amp Hrs. 1050
0935
Fixed Amp Hrs. 0935
Enter
Fixed Amp Hrs. 0935
38
Battery Type FLD
Enter
Battery Type FLD
1
Battery Type CTM.
Enter
Battery Type CTM.
▼▼
Finish Amps/100 4.5
Enter
Finish Amps/100 4.5
50
Finish Amps/100 5.0
Enter
Finish Amps/100 5.0
▼
Gassing V/C 2.40
Enter
Gassing V/C 2.40
00
Gassing V/C 2.00
Enter
Gassing V/C 2.00
▼
Lid V/C 2.70
Enter
Lid V/C 2.70
99
Lid V/C 2.99
Enter
Lid V/C 2.99
Program Review
Menu Tree 1 – 4
Program Review
ULTRA CHARGE
Summary of Contents for ULTRA CHARGE
Page 17: ...6 4 March 31 2005 193111 068 OPERATION ULTRA CHARGE RECHARGING CAPABILITY Figure 6 1 ...
Page 29: ...193111 068 UC2000 CONTROL FEATURES 7 12 Revised October 31 2005 Figure 7 2 ...
Page 37: ...193111 068 PROGRAMMING YOUR UC2000 CONTROL 8 8 Revised August 30 2005 Figure 8 1 ...
Page 63: ......
Page 64: ......
Page 65: ......
Page 66: ......
Page 67: ......
Page 68: ......
Page 69: ......