193111
-
055
OPTIONS
7
-
1 November 17, 2020
OPTIONS
The options listed in the following table of contents are those most commonly available. Special options not
listed here will be covered by enclosed
“
addendum
”
sheets.
OPTION NUMBER OPTION DESCRIPTION PAGE
002 Parallel Charging..
……………………………………….….7
-
1
003 Series Charging
……………………………………...……...7
-
1
101 Remote Charge Control and Ammeter
……….…..……..7
-
2
500 Fused Disconnect Switch and 24V Control Circuit
…...7
-
2
Parallel Charging –
Option 002
This option provides cables allowing two batteries to
be charged at the same time (batteries connected in
parallel to charger).
To prevent premature charger turn on, this option
requires the use of a battery connector with auxiliary
contacts (Anderson
“
SBX
”
or equivalent). The same
type connector must be specified on the battery and
vehicle. The connector on the battery must have the
auxiliary contacts jumpered together.
NOTE: The safety interlock circuit is protected
by an in
-
line 1 Amp AGC Fuse inside the battery
charger.
When charging two batteries, each must be of the
same voltage (or number of cells). The total rated
ampere
-
hour capacity of both batteries plus the voltage
(number of cells of only one of the batteries) must be
within the range of the charger. Refer to charger
nameplate for ratings. For example: two 12
-
volt
(6 cell), 225 ampere
-
hour batteries would make a 12
-
volt (6 cell), 450 ampere
-
hour load.
Operate this charger as instructed in Operation
chapter of this manual except that batteries are to be
connected as shown in Figure 7
-
1, plus the total
ampere
-
hour capacity must be used to calculate
charging time.
CAUTION: Make sure all connections are
made positive to positive and negative to
negative as shown.
Series Charging –
Option 003
This option provides a cable allowing two batteries to
be charged at the same time (batteries connected in
series to charger).
CAUTION: With the batteries required to be
connected in series, this charger cannot be
used to charge one battery only.
Both batteries must be of the same ampere
-
hour rating.
The total rated voltage (or number of cells) of both
batteries (add the two), plus the ampere
-
hour capacity
of only one battery, must be within the charger name-
plate range ratings. For example: two 12
-
volt (6
-
cell),
450 ampere
-
hour batteries would make a 24
-
volt
(12
-
cell), 450 ampere
-
hour load.
Figure 7
-
1 Parallel Charging Connections
Summary of Contents for AC1000 Control
Page 2: ......
Page 4: ......
Page 6: ...November 17 2020 193111 055 TABLE OF CONTENTS This page intentionally left blank...
Page 8: ...193111 055 INTRODUCTION 1 2 November 17 2020 This page intentionally left blank...
Page 12: ...193111 055 DESCRIPTION OF EQUIPMENT 3 2 November 17 2020 This page intentionally left blank...
Page 19: ...193111 055 OPERATION November 17 2020 5 4 Figure 5 1...
Page 30: ...193111 055 PARTS LIST 8 1 November 17 2020 Figure 8 1 A Case...
Page 32: ...8 3 November 17 2020 193111 055 PARTS LIST Figure 8 2 B Case...
Page 34: ...193111 055 PARTS LIST 8 5 November 17 2020 Figure 8 3 C Case...
Page 40: ......
Page 41: ......
Page 42: ......
Page 43: ...SCHEMATIC LEGEND NOTES...
Page 44: ......
Page 45: ......
Page 46: ......
Page 47: ......
Page 48: ......
Page 49: ......
Page 50: ......