Section 1
Page 1 - 2
Fixed Thermal Imaging System
Installation Guide
1.1 Summary Specifications
FTI-E-PSU:
Operating Temp Range:
0 to 50°C / 30 to 120°F
Sealing:
IP65
Power Requirement:
100 to 240V ac 1.0A 50/60Hz
EMC: EN61326
Safety:
EN61010-1
Camera
Operating Temp Range:
5 to 50°C / 40 to 120°F
*1 *2
Sealing:
IP65
Weight:
4.5kg
/
10lb
EMC: EN61326
IP
Address:
10.1.10.10X
(10.1.10.102
Default,
X
=
Rotary
Switch
Position)
Rugged Housing
Max ambient temperature: 85°C / 185°F
with
water
cooling
at
1
litre/
minute
@20°C
Weight:
15kg
/
33lb
Blower
Operating Temp Range:
-40 to 50°C / -40 to 120°F
Sealing:
IP65 with cover fitted
Refer
to
the
Blower
Unit
User
Guide
for
full
details
Weight:
28.5
kg
/
63lb
*1
Internal sensor value
*2
FTI800-x-xx-xx model is restricted to 10 to 45°C / 50 to 100°F