Maintenance and Servicing

  procedures not specifically explained in this manual 

must be performed only by a qualified technician.

cleaning, Maintenance, and Lubrication

1.  Wipe unit with a dry, lint-free cloth.  

Do not use solvents or abrasives.

2.  Remove battery if not in 

use for long periods.

3.  Store Meter in a dry location.

4.  Other than test leads, the battery, and 

fuses, there are no replaceable parts 
on this Meter.  

repairs should be 

done by a qualified technician.

Battery replacement

If the 

 sign appears on the Display, 

the battery should be replaced.

1.  Power off Meter and 

remove its Test Leads.

2.  Turn Meter over and remove screw 

on back cover.  Save the screw.

3.  Carefully remove battery cover and 

tilt stand from back of Meter.

4.  Remove battery from the 

battery compartment.

5.  Replace battery with the 

same type and rating.

6.  Replace battery cover and tilt stand.   

Fasten securely with saved screw.

note:

  Do not reverse the 

polarity of the battery.

Fuse replacement

1.  Power off Meter and 

remove Test Leads.

2.  Turn Meter over and remove screw 

from back.  Save the screw.

3.  Carefully remove battery cover and 

tilt stand from back of meter.

Screw

4.  Carefully pull the outside 

cover off the Meter.

5.  Remove four screws from back cover, 

one from each corner.  Save screws.

One screw at 

each corner.

Summary of Contents for 64014

Page 1: ...ease call 1 888 866 5797 as soon as possible Copyright 2018 by Harbor Freight Tools All rights reserved No portion of this manual or any artwork contained herein may be reproduced in any shape or form...

Page 2: ...sed to alert you to potential personal injury hazards Obey all safety messages that follow this symbol to avoid possible injury or death Indicates a hazardous situation which if not avoided will resul...

Page 3: ...the Meter have it serviced before use f The battery cover is open 5 Power this Meter using only the battery ies referenced in the Specifications Chart 6 Use caution when working near voltages above 3...

Page 4: ...may vary depending on battery condition 24 Use the proper settings terminals techniques and range for the tests performed Start with the range stated in the instructions 25 Do not apply voltage to th...

Page 5: ...5D 600V 1 0 of rdg 5D AC Current Ranges 200 A 2000 A 20mA 200mA 10A AC Current Accuracy 200 A 20mA 1 0 of rdg 3D 200mA 1 2 of rdg 3D 10A 1 5 of rdg 10D Resistance Ranges 200 2k 20k 200k 2M 20M Resist...

Page 6: ...use read the EntirE iMpOrtant SaFEty inFOrMatiOn section at the beginning of this manual including all text under subheadings therein before set up or use of this product Functions range Button cOM Ja...

Page 7: ...Display Symbol Description autO Auto range mode Data Indicates that display data is being held Diode test Continuity buzzer Battery low indicator Dc Direct current ac Alternating current c F Celsius F...

Page 8: ...splay 1 To activate hold press the HOLD Button The reading will be held on the Display and the symbol will appear 2 Press HOLD again to release the hold ran Button The ran function allows you to manua...

Page 9: ...ll beep and the Non Contact Voltage Indicator will flash 3 Release the ncV Button to stop voltage detection WarninG Even if no indication is given voltage may still be present Do not rely solely on NC...

Page 10: ...ack Plug red test lead into input Jack 2 Turn Rotary Switch to the position 3 Press Func Button to choose between AC and DC voltage 4 While observing polarity carefully touch exposed conductors with t...

Page 11: ...Measurement Measure circuit resistance up to 20M ohms WarninG To prevent electric shock turn off all power and fully discharge capacitors in the circuit under test before measuring note When measuring...

Page 12: ...ck fuses before making current measurements To prevent damage to the meter be sure to use the correct input jacks 1 Turn the Rotary Switch to the appropriate position depending on the amperage of the...

Page 13: ...lug the red lead to the input Jack Plug the black test lead into cOM jack 3 Connect the red test lead to the positive terminal of the battery and the black test lead to the negative terminal of batter...

Page 14: ...the sign appears on the Display the battery should be replaced 1 Power off Meter and remove its Test Leads 2 Turn Meter over and remove screw on back cover Save the screw 3 Carefully remove battery co...

Page 15: ...and remove from its bracket Make note of the rating F2 400ma F1 10a 8 Replace with new fuse of the same type and rating 9 Rejoin the covers being careful to not pinch wires Secure covers with the four...

Page 16: ...o the above limitation of exclusion may not apply to you THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS To take a...

Reviews: