Amersham Pharmacia Biotech INV-907 Instructions Manual Download Page 8

Important user information

WARNING!
The Warning sign is used to call attention to the
necessity to follow an instruction in detail to avoid
personal injury. Be sure not to proceed until the
instructions are clearly understood and all stated
conditions are met.

CAUTION!
The Caution sign is used to call attention to
instructions or conditions that shall be followed to
avoid damage to the product or other equipment. Be
sure not to proceed until the instructions are clearly
understood and all stated conditions are met.

Note
The Note sign is used to indicate information
important for trouble-free or optimal use of the
product.

Should you have any comments on this instruction, we
will be pleased to receive them at:

Amersham Pharmacia Biotech
SE–751 84 Uppsala
Sweden

Trademarks

ÄKTA and UNICORN are trademarks of Amersham
Pharmacia Biotech Limited or its subsidiaries.

Amersham is a trademark of Nycomed Amersham plc.
Pharmacia and Drop Design are trademarks of
Pharmacia & Upjohn Inc.

Terms and Conditions of Sale

All goods and services are sold subject to the terms
and conditions of sale of the company within the
Amersham Pharmacia Biotech group which supplies
them.  A copy of these terms and conditions of sale is
available on request.

Adresses

Amersham Pharmacia Biotech UK Limited
Amersham Place  
Little Chalfont  
Buckinghamshire 
England HP7 9NA

Amersham Pharmacia Biotech AB
SE-751 84  Uppsala  
Sweden

Amersham Pharmacia Biotech Inc
800 Centennial Avenue   
PO Box 1327   
Piscataway   
NJ 08855 USA

© Amersham Pharmacia Biotech AB 1998 

– All rights reserved

TC information ab, Uppsala. Printed in Sweden by TK i Uppsala AB, October 1998

56-8101-01_AC.qxd  1998-10-26 11:45  Sida 8 (1,1)

Summary of Contents for INV-907

Page 1: ...the valve 1 Connect the valve with two UniNet cables as a part of the UniNet 2 chain 2 Set the ID switch at the bottom to the required valve number 0 9 The number should correspond to that used in UN...

Page 2: ...3 Operation The valve is controlled from UNICORN When used as an injection valve use the instruction InjectionValve in System Control Manual Flowpath The valve can be set in 3 positions LOAD position...

Page 3: ...op volume Complete filling 2 5 times the sample loop volume Partial Filling Partial filling is used when high recovery is required Partial filling allows the injected volume to be changed without chan...

Page 4: ...pprox 5 times the sample loop volume should be used to flush the loop and ensure that all sample is injected onto the column Storage Overnight The valve can be left filled with a buffer Weekend or Lon...

Page 5: ...socket 2 Check the ID switch on the valve The ID number should correspond to the number set in UNICORN 3 Check the UniNet cable and replace if required The valve is switching to wrong position The val...

Page 6: ...ysical data Internal volume Pos 1 LOAD Port 1 7 9 l Port 2 3 5 l Port 4 6 8 l Pos 2 INJECT Port 1 2 7 l Port 3 5 6 l Port 6 7 9 l Pos 3 WASH Port 2 4 8 l Port 5 7 9 l Flow channel diameter 0 8 mm Valv...

Page 7: ...1 18 1113 81 Superloop 50 ml 1 18 1113 82 Superloop 150 ml 1 18 1023 85 Cable UniNet 0 7 m 1 18 1109 74 Mounting bracket 1 18 1109 11 Teflon tubing i d 1 8 o d 3 16 3 m 18 1112 47 Tubing connector for...

Page 8: ...Biotech SE 751 84 Uppsala Sweden Trademarks KTA and UNICORN are trademarks of Amersham Pharmacia Biotech Limited or its subsidiaries Amersham is a trademark of Nycomed Amersham plc Pharmacia and Drop...

Reviews: