a. Depending on the nature of the fouling, a soak period may be necessary. 

If the membranes are not heavily fouled, proceed to step 11. 

b. In cases of heavy fouling, turn off the RO and CIP pump and allow the 

system to soak for a minimum of 30 minutes.*   

*  Contact AmeriWater Technical Support or your local AmeriWater dealer for custom cleaning procedures if 

necessary. 

c.  After the soak time, turn on the CIP pump and RO, and allow the cleaning 

solution to recirculate again for 30 minutes. 

12.  Disconnect the pump outlet hose from the CIP tank and direct the hose to a 

drain. Continue running to drain until the CIP tank is empty (some solution 
may need to be manually dumped out of the CIP tank). 

CAUTION:

Neutralization of the spent cleaning solution may be required 
by local regulations. Verify the requirements of local 
regulations prior to emptying the cleaning solution into the 
drain.  Use an approved waste container for chemical waste 
disposal if required.

13.  After removing the spent chemical from the CIP2 tank, and with the CIP2 

pump discharge directed to drain, turn on the MRO and allow fresh water to 
flow into and through the RO and CIP2 for 10 minutes or until the pH of the 
water at the pump discharge is neutral (between 6 and 8). 

14.  Proceed to the low pH cleaning.   

WARNING: Never allow AmeriClean A and AmeriClean B to mix!   Mixing the 

chemicals will cause an exothermic reaction which may result in 
serious injury and damage to the equipment!  Flush the system 
thoroughly and verify the pH of the reject water is neutral prior to 
switching chemicals! 

NOTE: 

The 20” filter housings may trap some left over chemical solution causing 

rinse out times to be high. To shorten the rinse time, remove and dump the filter 
housing, then reinstall in the system. This allows the housing to fill with fresh 
water and reduces time required for rinsing. 

Summary of Contents for CLEAN IN PLACE CIP2

Page 1: ...Part Number 98 0008 Revision G CLEAN IN PLACE MODEL CIP2 Manufactured With Pride In The USA www ameriwater com 800 535 5585 AmeriWater 3345 Stop 8 Rd Dayton OH 45414...

Page 2: ......

Page 3: ...TABLE OF CONTENTS 1 OBJECTIVE 1 2 CHEMICALS REQUIRED 1 3 SET UP 2 4 INSTALLATION DIAGRAM 4 5 HIGH pH CLEANING 6 6 LOW pH CLEANING 8 7 AMERIWATER IRO SPECIFIC INSTRUCTIONS 10 8 SPARE PARTS LIST 10...

Page 4: ...e foulants from polyamide thin film composite 3 lb 1 110 ml of AmeriClean B powder is required per membrane cleaning AmeriClean B effectively removes the following foulants Silt Microbiological Colloi...

Page 5: ...lean water to remove any debris or contamination after un packing or after the CIP system has been in storage 3 Install two of the long hoses into the upper ports on the tank by screwing the 1 pipe th...

Page 6: ...ump outlet hose to the reverse osmosis water INLET only WARNING If the PRODUCT hose PERMEATE is momentarily pressurized due to an incorrect connection the CIP in reverse flow the membranes will be des...

Page 7: ...ided to fit the AmeriWater MRO3 4 5 MROX MROZ models AmeriWater Industrial RO systems and other common RO systems Select the correct fittings fittings included to mate to the RO system at your facilit...

Page 8: ...THE QUICK CONNECT FITTING CONNECT CONCENTRATE OUTLET TO THE CONCENTRTAE PORT ON THE CIP TANK DISCONNECT THE WEDGIT QUICK CONNECT FROM THE PERMEATE OUTLET CONNECT THE PERMEATE OUTLET TO THE PERMEATE PO...

Page 9: ...ING Wear appropriate eye and skin protection when handling the membrane cleaning chemicals The cleaners are high and low pH chemicals and may cause severe chemical burns Read the MSDS for further info...

Page 10: ...ations prior to emptying the cleaning solution into the drain Use an approved waste container for chemical waste disposal if required 13 After removing the spent chemical from the CIP2 tank and with t...

Page 11: ...eaning solution is recirculating and flowing from the drain hose inside the CIP tank 6 Allow the cleaning solution to recirculate for a minimum of 50 minutes a Depending on the nature of the fouling a...

Page 12: ...normal fault alarms to be active 13 Close the cover on the MRO and turn on the electrical power 14 To return the MRO to service close the PRODUCT AND REJECT valves going to the CIP2 then open the IN S...

Page 13: ...ut of the normal discharge hoses for PRODUCT WATER or REJECT WATER 2 Turn OFF the power disconnect prior to opening the controller 3 After placing the CIP Switch in the ON position close the controlle...

Page 14: ...INSx1IN FPT POLYGLASS 16 14520215 Adapter 1 0 Male NPT X 1 0 HB PP 17 15650100 CLAMP HOSE 1 SST 18 041531829 NIPPLE 75 X CL PVC80 19 046530953 Bush 1 0 X 0 75 THRD PP 20 16UMA100 Q CON COUP THD STEM x...

Reviews: