American TIM-900 Installation And Use Manual Download Page 1

E

ng

lis

h

TIM-900

Installation and Use Manual

Dispensing nozzle for oil 

and industrial fluids

BULLETIN M0095A REV.1

Summary of Contents for TIM-900

Page 1: ...English TIM 900 Installation and Use Manual Dispensing nozzle for oil and industrial fluids BULLETIN M0095A REV 1 ...

Page 2: ... the lines E8 Flow rate check F Using the TIM 900 p 16 F1 Dispensing in MANUAL mode F2 Dispensing in AUTO mode G Customizing the TIM 900 p 21 G1 Customization menu G2 Frequently used PRESET values G3 Units of measurement G4 Decimal digits G5 Automatic RESET G6 Stop precision in AUTO mode G7 Calibration H Maintenance of the TIM 900 p 31 H1 Replacing the batteries H2 Cleaning the filter L Product Id...

Page 3: ...ection of the Number of Decimal Digits Calibration etc At least one skilled Operator hereinafter referred to as the Manager must know this data in order to allow the Operators to use the METER correctly The Manager must read thoroughly all paragraphs concerning the Manager and the Operator The following symbols are used to highlight important notes and information Warning Warning This symbol highl...

Page 4: ...llows the user to PRESELECT the amount to be supplied and automatically stops the dispensing when the pre set amount has been reached The TIM 900 integrates Warning This manual is an essential and integral part of the product and must be handed over to the personnel who carry out the installation use and maintenance of the TIM 900 Read the indications given in this manual as they provide important...

Page 5: ...er The large filtering surface guarantees a reduced pressure loss Rubber swivel cover During installation the swivel may be equipped with a rubber cover to prevent the swivel itself or the metal end of the flexible hose from damaging the vehicle body This cover is available in different colours which can be used as a colour code to identify the dispensed product easily An external shock resistant ...

Page 6: ...ch total 4 digits floating point 2 Totals 7 digits 3 Indication of the Total type TOTAL Resettable TOTAL 4 Indication of the Unit of Measurement Qts Quarts Pts Pints Lit Liters Gal Gallons 5 Indication of operation in AUTO mode Warning The LCD automatically turns off if the TIM 900 is not used for a certain period Trigger The valve is in CLOSED position The valve is in MAXIMUM OPEN position The li...

Page 7: ...y the Resettable TOTAL Meter To guarantee an accurate measurement of the dispensed amount the TIM 900 uses the principle of the oval gears Multi position extension To guarantee an easy use the TIM 900 is equipped with a multi position extension It can be positioned by the operator in 5 different pre set positions within a 75 range The extension is not free to rotate but it can be only by activatin...

Page 8: ...In addition the automatic dripples valve can be rotated of 240 8 ...

Page 9: ...ption before starting dispensing the Operator must Select the desired amount by means of the TIM 900 keys as explained in paragraph F2 Confirm the selected value thus entering the AUTO mode TIM 900 displays the message AUTO and is ready to dispense automatically without requiring the presence of the Operator the value previously indicated on the Batch Total The operator has to check the dispensing...

Page 10: ...he desired value is still in progress but the AUTO mode has not yet been entered by confirming the displayed value The TIM 900 automatically unlocks the trigger thus stopping the dispensing when the predetermined value has been reached However during dispensing in AUTO mode it is possible to stop dispensing manually before the desired value is reached by unlocking the trigger To unlock the trigger...

Page 11: ...be freely chosen by the Installer as they do not influence the maintenance of the TIM 900 Warning The TIM 900 has been designed to be used as a component of a centralized system for the distribution of oils and other industrial fluids which must be manufactured and installed by specialized personnel in compliance with the standards relevant to such a pressurized system To explain the installation ...

Page 12: ...se the line pressure For the dismounting of the TIM 900 only Remove the rubber cover from its coupling on the swivel and move it along the flexible hose in order to have easy access to the swivel By means of two wrenches unscrew the threaded end of the flexible hose from the swivel Be careful to collect any oil leakage into a suitable container If a dripless valve is installed at the end of the no...

Page 13: ...m and must be carried out by trained and qualified personnel in compliance with the procedures set down by the installer Make sure that the threaded end fitted on the flexible hose is suitable for the swivel of the TIM 900 provided with Check that the TIM 900 to be installed is complete and in good condition making sure that the filter is clean and correctly installed see paragraph H2 The filter o...

Page 14: ...outlet A blocks the TIM 900 the second one tightens nut C of end D Before locking nut C orientate valve E An improper tightening of the extension may cause it to become loose thus endangering persons or things Tighten the ring nut with a torque wrench setting at 3 5 Kg per metre Warning Fit the rubber cover of the swivel into the flexible hose in the direction indicated in the figure making it sli...

Page 15: ... present both inside the flexible hose downstream the nozzle and in the other lines of the system To purge the air and to guarantee a steady flow and a correct calculation of the amount dispensed two persons must act as follows With the shut off valve still closed insert the extension of the TIM 900 into the opening of a container of a suitable capacity to avoid sprays or spillage which may occur d...

Page 16: ...rom the rain snow or direct sunrays If the TIM 900 is off type RESET to re start it The TIM 900 displays The TIM 900 can be used as a normal nozzle if the Operator does not want to pre set an automatic stop value The TIM 900 can be programmed to display the last amount dispensed until the RESET button is pressed or to automatically reset the Batch Total a few minutes after the end of the dispensin...

Page 17: ...procedures The TIM 900 allows the user to set directly the PRE SET value by means of the numeric keys To reset the resettable Total press and hold down the RESET key The TIM 900 will display To select a new PRESET value for example 12 3 use the numeric keys Selected value English Resetting the Batch Total Resetting the Total Resettable total Resettable total Dispensing To Dispence in AUTO mode F2 ...

Page 18: ...00 allows the operator to use the most frequently used PRESET values without having to set them by means of the numeric keys In particular the TIM 900 stores The last PRESET value AUTO LAST Five different PRESET values AUTO 1 AUTO 5 The AUTO LAST value is automatically updated each time a new PRESET value is set by means of the keypad The last value used replaces the previous one in the memory The...

Page 19: ...hat you have not yet entered the AUTO mode by confirming the displayed value During this phase it is possible to modify the AUTO value being displayed by means of the numeric keys The modification of the displayed AUTO value however does not change the stored AUTO value To modify the latter it is necessary to follow the procedure indicated in paragraph G2 Press AUTO again The TIM 900 displays the ...

Page 20: ...ensed amount is added to the previous one in AUTO mode The PRESET value previously set displayed in the Total starts blinking to indicate that the pre set value has been exceeded Pull the trigger completely and then release it The trigger thus remains locked in open position Now dispensing can continue even if the Operator is not present To start dispensing To stop manually dispensing in progress ...

Page 21: ...libration factor K factor If the TIM 900 displays the Resettable Total wait a few seconds until the METER automatically displays the Total Only in this condition is it possible to enter the customization Menu To access the various customizing functions and to select the desired options two different actions are indicated on the keys This symbol indicates that it is necessary to press the key brief...

Page 22: ...own the AUTO key until the TIM 900 displays See paragraph G5 for the activation modes Setting the most frequently used PRESET values Selecting the Number of Decimal Digit Selecting the Unit of Measurement Activating the Auto RESET function To go to the next activity Blinking Blinking point Now you have entered the following activity Now you have entered the following activity To go to the next act...

Page 23: ... frequently used PRESET values AUTO 1 AUTO 5 which can be rapidly recalled without having to set them each time by means of the numeric keys Use the numeric keys to set a new PRESET value which will replace the one previously stored in the memory The first time these activities are accessed all the PRESET values stored AUTO 1 AUTO 5 are set to zero Warning Modification the precision Stop factor PS...

Page 24: ...o accept the setting of the PRESET value AUTO 2 Each time the AUTO key is pressed the next AUTO value is displayed Press and hold down the AUTO key to go to the next activity Press RESET to exit from the customization menu Warning If for example you want to assign the value 31 2 to AUTO 1 press The TIM 900 will display Blinking Index of the PRESET value AUTO 2 Blinking 24 ...

Page 25: ...n GALLONS Go on pressing AUTO until the desired Unit of Measurement is displayed Press and hold down the AUTO key to go to the next activity Press RESET to exit from the customization menù The TIM 900 allows the user to select one of the following Units of Measurement Warning Warning The modification of the Unit of Measurement does NOT require a new Calibration see paragraph G7 If the TOTAL indica...

Page 26: ...plays Press AUTO to modify the selection Press AUTO again to go back to the previous selection Press and hold down the AUTO key to go to the next activity Press RESET to exit from the customization menu Warning Independent of the selection carried out the Batch Total supplied is never reset if the dispensing operation has been carried out in AUTO mode Warning The function described in this paragra...

Page 27: ...actor called PS factor The Manager during the customization of the TIM 900 can select a PS factor between ZERO and FIVE By selecting PS 0 a pre closing equal to ZERO is set PS 1 PS 2 PS 3 PS 4 PS 5 the MAXIMUM pre closing is set The higher the flow rate the higher the selected PS value If you select a too high PS value the dispensed amount may be lower than the pre set value by some hundredths of ...

Page 28: ...nished when the level of the fluid reaches the graduated area of the Calibrated Container During dispensing the TIM 900 displays On site calibration by dispensing into a calibrated container The TIM 900 is equipped with a meter with high precision oval gears pre calibrated in the factory At delivery all TIM 900 are given the same calibration factor K Factor 1 000 This calibration factor guarantees...

Page 29: ...lling the trigger of the TIM 900 and then releasing it very quickly After dispensing wait a few minutes to allow the removal of possible air bubbles from the Calibrated Container Read the Real value only at the end of this phase as the level in the container may decrease Do not wait more than 15 minutes as the TIM 900 will exit from the menu and it will no longer be possible to complete the calibr...

Page 30: ...ite calibration of the meter If you wish to verify the result of this calibration carry out a normal dispensing in the same Calibrated Container without re entering the Calibration function in the Customization menu CAL End Blinking alternatively New K Factor After a few seconds the TIM 900 automatically exits from the customization mode and starts using the new Calibration Factor The TIM 900 is r...

Page 31: ... New K Factor After a few seconds the TIM 900 automatically exits from the customization menu and starts using the new Calibration factor As soon as the message bAtt appears on the display dispensing in AUTO mode is immediately stopped and it is no longer possible to lock the trigger in open position Warning This prevents the unit from continuing to dispense in AUTO mode even if the PRESET value h...

Page 32: ...a short SELF TEST Complete lighting of LCD Complete stop of LCD Display of serial number of electronic board Normal operation mode E Place the cover again and fix the battery pack by screwing the four screws Warning Warning The replacement of the batteries does not cause any data loss The customization of the TIM 900 previously set remains operational at the next re starting The TIM 900 is equippe...

Page 33: ...r with the utmost care If the filter is in good condition and is correctly installed it guarantees the good operation of the TIM 900 thus avoiding any dust or foreign bodies which may lock or damage the TIM 900 valve E Reassemble the TIM 900 according to the instructions given in paragraph E6 F Fix the connection again and tighten it at 20 Nm English Some technical data of the TIM 900 which is ess...

Page 34: ... 150 KPa 22 psi with dripless valve 450 KPa 65 psi Units of measurements Liter Gallon Pint Quart selectable by the operator Indications Batch total floating point 0 000 to 999 9 units Total Resettable total 999 999 units Presettable amount 0 1 to 99 9 units Batteries 4 x AA size 1 5 Volt Expected life 1 year up to 10 000 AUTO operation per year AUTO mode automatic inhibition when low battery indic...

Page 35: ...90 340 184 Ø BSP 1 2 Ø NPT 1 2 115 285 7 5 9 4 6 0 6 0 English Dimensions M2 35 ...

Page 36: ... spare parts please always specify Position No of spare part Model Serial No Warning Position No Part description Q ty 1 Rubber Protection 1 2 Filter Unit 1 3 Locking Ring 1 4 Battery Pack 1 5 Batteries 1 5 V size AA 4 6 Articulated End 1 Serial number 36 ...

Page 37: ...onic components in accordance with the instructions of 2002 96 EC see text of Directive below ENVIRONMENTAL INFORMATION FOR CUSTOMERS IN THE EUROPEAN UNION European Directive 2002 96 EC requires that the equipement bearing this symbol on the product and or its packaging must not be disposed of with unsorted municipal waste The symbol indicates that this product should be disposed of separately fro...

Page 38: ......

Page 39: ......

Page 40: ......

Reviews: