Note:

 American Time recommends testing each digital clock at the installation location prior to 

mounting. The Remote Transmitter must be installed and transmitting. Clocks should be installed 

within 24 hours of installing the Remote Transmitter. After 24 hours, the Remote Transmitter will 

enter Quiet Mode. Quiet Mode can be manually toggled off. Reference Appendix F for more details 

on Quiet Mode. 

Plug AC wall adapter into 120vac wall outlet. Adjust time to an incorrect setting using  

 

 

the Set 1 or Set 2 buttons. For American series digital clocks, there are no buttons. See    

 

Step 2.

Verify synchronization takes place within 2-5 minutes. American series digital clocks will    

 

display “U 40” or other message at startup and synchronize within 1 minute of power-up.

Digital Clock Manual Operation Instructions (Does Not Apply for American Series)

There are eight modes. They are time, month/day, year, 12/24 hour format, Daylight Saving Time, time zone location, 
brightness and time correction. The display button will display these modes. To modify settings in any mode use the 
Set 1 and Set 2 buttons.

n

Note:

 If the SiteSync IQ Remote Transmitter is operating properly, there is no need to set the digital clocks. They 

should automatically correct themselves from the Remote Transmitter every minute when they are receiving a signal. 
The only functions that you may wish to change are the time format (12/24 hour) and time zone code.
To manually set the digital clock, complete the following:

u

  Press the display button to begin the sequence.

v

 

Set the Month and Day. The Set 2 button will advance the month and the Set 1 button will advance the day.

w

 

Press the display button to continue to the year selection

x

 

Set the year. The Set 2 button decreases the year and the Set 1 button increases the year.

y

 

Press the display button to continue to the 12/24 hour selection

y

 

Set the time format to 12 or 24 hour using the Set 1 or Set 2 buttons.

 

Press the display button to continue to Daylight Saving Time.

 

Set the Daylight Saving Time. The Set 2 button increases the Daylight Saving Time code and the Set 1  

 

 

button decreases the Daylight Saving Time zone.

 

n

Note:

 0 = No Daylight Saving Time - with SiteSync IQ Remote Transmitter automatic synchronization

 

           1 = Automatic Daylight Saving Time (USA)

  Press the display button to continue to the time zone settings. A 7 will be displayed as the first digit  

 

 

indicating the time zone selection.

 

Set the time zone code. The Set 2 button increases and the Set 1 button decrease the time zone code.

 

n

Note:

 0 should be used for wireless operation. Time zone codes run from 0 to 31. 0 is UTC time. Codes    

 

1 to 12 add to UTC and 31 to 21 subtract from UTC. For example: Code 5 is UTC + 5 hours and Code 26 is UTC  

 

- 5 hours.

 

Press the display button until the time is displayed.

 

Set the time. The Set 1 button advances the hours and the Set 2 button advances the minutes.

11

12

Time

Month

Year

12/24 hour

Daylight Set

Time Zone

Brightness

Flowchart: Digital Clock Modes

Summary of Contents for H004663

Page 1: ...Installation and Operation Manual Part H004663 Rev 2 July 2013 Wireless Remote Transmitter...

Page 2: ...s FCC Warning This equipment may generate or use radio frequency energy Changes or modifications to this equipment may cause harmful interference unless the modifications are expressly approved in the...

Page 3: ...ote Transmitter Connect Web Interface 12 20 Installation Instructions for Clocks Analog AA AA with Battery Pack and AC Clocks 21 Digital Clocks 22 24 Troubleshooting Remote Transmitter 25 Ethernet 26...

Page 4: ...aylight Saving Time Support for time zone clocks up to eight unique time zones Support for 5 10 25 and 40 watt internal transmitters SiteSync IQ Wireless Remote Transmitter Specifications Physical Dim...

Page 5: ...at except American series digital clocks which use the time format display of system controller 1 second accuracy to master Black anodized aluminum frame except American series digital clocks use stee...

Page 6: ...e Transmitter indoors b Locate within 10 ft of planned location for antenna c Locate near an electrical outlet 120vac d Rack or shelf mount e Locate in an area with a network drop or run a Ethernet da...

Page 7: ...d be lower than other nearby building features or lightning rods to reduce the potential for lightning strikes e Place the antenna in an area that is easily accessible for maintenance and inspection f...

Page 8: ...talled outdoors the location of the antenna should be lower than other nearby building features or lightning rods to reduce the potential for lightning strikes g Identify a location in the proximity o...

Page 9: ...7 Firewall Port 123 for SNTP or 13 for Daytime Protocol open 8 SNTP Server Address Alternate SNTP Server Address See Appendix A for a list of Internet Time Server addresses or use the address of a ser...

Page 10: ...DHCP server the default address of the Remote Transmitter will be 192 168 10 10 In this situation directly connect an Ethernet patch cable from the Remote Transmitter to a computer that is on the same...

Page 11: ...the Unit IP Address Subnet Mask and Gateway IP assigned from your Network Administrator and recorded in the Ethernet Configuration section on page 9 The Update button must be pressed for changes to t...

Page 12: ...ocation doesn t observe DST select OFF from the drop down menu 9 To confirm proper setup Enable the On Demand Sync Ethernet button and press Sync Now If successful a green check mark will appear next...

Page 13: ...ayed by Ethernet 1 is the first time Server IP address and Ethernet 2 is the Alt Time Server IP address 4 Software Version This will display the current software version of the SiteSync IQ Remote Tran...

Page 14: ...will be displayed The user may choose the option in which they would like to synchronize their time and press Sync Now The time and date will be updated automatically if successful indicates a succes...

Page 15: ...nt Tab allows you to create edit print and save your schedules Figure 3 1 View This row is for sorting which events should be displayed in the table below If Schedule or Day is selected an additional...

Page 16: ...ents Does not appear for Regular Events Date may not be in the past e Message Message to be displayed on Digital Clocks Does not apply for Schedule Change Events Reference Manual Activation section of...

Page 17: ...duration The Update button must be pressed for changes to take effect 4 Switching 1 This allows the user to schedule a schedule change For example the image above may be a typical example of a winter...

Page 18: ...This message number is only applicable if you have an SQAxxxxxxC 1 6 digital clock A message number of 0 disables this feature 4 Countdown Duration This is used to select the duration of the countdown...

Page 19: ...pdate button to save the configuration 4 Time Server IP Address This displays the IP address of the time server After changing this field press the Update button This is referred to as Ethernet 1 whic...

Page 20: ...ed for this change to take effect 3 Sync Time This displays the time of day that the synchronized time pulse is sent The pulse is only sent once a day and is programmed to the nearest minute The Updat...

Page 21: ...ay Format This allows the user to change the Time Display Format The format chosen will also be displayed on our American Digital Series Clocks The Update button must be pressed for changes to take ef...

Page 22: ...ter is installed and transmitting u Connect clocks to AC power with cord kit or Molex kit and confirm green is lit after power up nNote If the LED does not flash within 30 seconds disconnect the barre...

Page 23: ...res through the enclosure base x Make electrical connections hot neutral ground wires to non switched electrical circuit wiring using UL approved wire nuts Route field wiring away from sharp projectio...

Page 24: ...Time 24 Wireless Remote Transmitter Installation Manual Glossary Appendix Troubleshooting Clock Installation Transmitter and System Setup Introduction American Time User Notes SiteSync IQ Installatio...

Page 25: ...rom the Remote Transmitter every minute when they are receiving a signal The only functions that you may wish to change are the time format 12 24 hour and time zone code To manually set the digital cl...

Page 26: ...mmeter will show a Short If the unit is in good condition it will show a high resistance A replacement discharge tube is available from the manufacturer or the entire lightning arrestor AT part H00349...

Page 27: ...ync IQ Remote Transmitter is configured properly 3 Change the Time Server IP address to a different timeserver among those listed in Appendix A Perhaps the timeserver that the remote transmitter is at...

Page 28: ...in this format http xxx xxx xxx xxx or Host Name http sqrtxxxxxx and click Enter nNote The connecting computers IP address must be on the same subnet Example 1 IP address Example 2 Host Name 3 If the...

Page 29: ...valid signal is received LED will flash green once signal is received AC Clocks a Press and release the reset button on the back of the receiver with power supplied b Watch for LED to flash will flash...

Page 30: ...gital clock nNote American series has signal indicator dot in the lower right corner of the clock display or colon dots flash when wireless time update signal is received b Wait until the top of the m...

Page 31: ...31 American Time Wireless Remote Transmitter Installation Manual Glossary Appendix Troubleshooting Clock Installation Transmitter and System Setup Introduction User Notes...

Page 32: ...ansmitter simply enter the IP address of the Remote Transmitter as the time server address for the computer or device In Windows XP 1 Right click your clock and then click Adjust Date Time 2 Click the...

Page 33: ...n EST EDT 5 4 YES 08 USA Hawaii HST 10 10 NO 09 USA Indiana East 5 5 NO 10 USA Mountain MST MDT 7 6 YES 11 USA Pacific PST PDT 8 7 YES 12 USA Midway Island Samoa SST 11 11 NO 13 USA Wake Islands WAKT...

Page 34: ...d Software Version wSerial Number This displays the IQ Remote Transmitter s serial number Serial Number xUnit Configuration This displays the model configuration of the IQ Remote Transmitter set at th...

Page 35: ...troduction Appendix D SiteSync IQ Remote Transmitter Port Diagrams Front of Remote Transmitter A Remote Transmitter ON LED B Ethernet Link Activity LED C Radio Push to talk LED D Radio Data Transmit L...

Page 36: ...the top and or bottom of each minute However in Quiet Mode the TX will not appear every 30 seconds Verify equipment is transmitting by resetting a clock in a known good signal area by completing the f...

Page 37: ...g the initial system installation After the initial 24 hours Quiet Mode will be designated on the General tab of Remote Transmitter Connect as follows After the initial 24 hours the remote transmitter...

Page 38: ...teway IP Address The address value for the Gateway device on the network see Gateway GPS Global Positioning System A constellation of satellites operated by the United States Military US Naval Observa...

Page 39: ...computers routers switches etc and the rest of the network Synchronization The process of bringing two clocks or time sources into phase so their difference is zero In the case of a timekeeping syste...

Reviews: