3
ADJUSTING SENSOR RANGE
C
J
BLINKING LED
1
DETECTION ZONE
400 TO 800 mm (15-3/4" x 31-1/2")
(Factory Setting: 600 mm (23-5/8")
1" - 2" (30 - 50 mm)
BLINKING LED
1
4
3
5
Note: The detection distance is preset and ideal for most
installations. Should an adjustment be required, follow the
steps below.
1.
Remove the connections from the CONNECTOR LOCKING
DEVICE (
5
). Disconnect the 27" EXTENSION CABLE (
3
) from the
10' EXTENSION CABLE (
4
), and reconnect.
Note: You have 5 seconds to begin entering the program code
after power connection is made.
2.
While the SENSOR CONTROL LED (
1
) is blinking
slowly, place your hand 1 to 2 in. (30-50 mm.) in front of the
sensor.
3.
When the LED (
1
) stops blinking and stays “ON”, move your hand
to the desired position from sensor and hold in place until the
LED (
1
) begins to blink again.
Note: Detection Zone is 400 - 800 mm (15-3/4"x 31-1/2").
(Factory Setting: 400 mm (15-3/4")
4.
Once the SENSOR CONTROL LED (
1
) begins to blink again,
remove your hand from the detection zone. When the flashing
stops, the detection distance is set.
5.
Actuate the FLUSH VALVE:
A)
Cover sensor with hand for 10 seconds.
NOTE: Stand outside of sensor detection area.
B)
Remove hand from detection area; unit will
flush in approximately 3 seconds.