STOPPER INSTALLATION PROCEDURE

Locked Mode: 

Look at the Plastic Loop at the bottom of the Stopper and notice

that the Loop is on one side of the Stopper. 

Fig.

 

G.

To install the stopper in 

“Locked”

 mode, insert the Stopper into

the Drain so that the Plastic Loop is facing toward the 

rear

 of the

Sink and the American Standard logo is facing 

front

. Rotate

Stopper slightly if necessary so that the Stopper slides all the

way down.

Fig.

 

G.

Re-install the Cam into the Drain, rotating the Cam if necessary

to make sure it is fully inserted. 

Fig.

 

J.

Re-install the Cam Cap, making sure the guide teeth are facing

outward. If the Cam Cap does not “snap” into place, then rotate

the Cam to make sure it is fully inserted. 

Fig.

 

K.

Re-attach Cable. See “CABLE ADJUSTMENT PROCEDURE” in

Troubling Shooting Guide to complete installation. Stopper will be

in 

“Locked”

 mode and not be removable.

Unlocked Mode: 

Look at the Plastic Loop at the bottom of the Stopper and notice

that the Loop is on one side of the Stopper. 

Fig.

 

H.

To install the stopper in 

“Unlocked”

 mode, insert the Stopper into

the Drain so that the Plastic Loop is facing toward the 

front

 of the

Sink and the American Standard logo is facing 

rear

. Rotate Stopper

slightly if necessary so that the Stopper slides all the way down.

Fig.

 

H.

Re-install the Cam into the Drain, rotating the Cam if necessary

to make sure it is fully inserted. 

Fig.

 

J.

Re-install the Cam Cap, making sure the guide teeth are facing

outward. If the Cam Cap does not “snap” into place, then rotate

the Cam to make sure it is fully inserted. 

Fig.

 

K.

Re-attach Cable. See “CABLE ADJUSTMENT PROCEDURE” in

“Troublingshooting Guide” to complete installation. Stopper will be

in 

“Unlocked”

 mode and removable.

Fig.

 

J.

Fig.

 

K.

INSTALL
CAM CAP

CAM

INSTALL CAM

The Stopper can be installed two ways, “Locked” Mode (Stopper cannot be
removed) or “Unlock” Mode (Stopper is removable).

Locked Mode

(Vandal Proof)

Fig.

 

G.

LOGO

Unlocked Mode

180˚

LOGO

DRAIN

Fig.

 

H.

6

M 9 6 8 8 6 5   R e v .   1 . 2

Summary of Contents for Triumph 7034

Page 1: ... firmly Fig B 2 2 1 4 3 3 4 HAND TIGHTEN Your new American Standard faucet is designed to work only with the Speed Connect Drain Helpful tips for removing your current drain can be found in the Troubleshooting section of these instructions To ensure that your installation proceeds smoothly please read these instructions carefully before you begin Fig A Fig B 1 Congratulations on purchasing your Am...

Page 2: ... COVER 1 Remove CARDBOARD SPACER 2 from under DRAIN POP UP 3 Fig A 2 REAR OF SINK 4 5 6 3 1 SINK DRAIN HOLE FLAT SIDE OF GASKET MUST FACE DOWN 1 2 Fig A 2 1 FLAT SIDE OF GRAY LOCKNUT MUST FACE UP INSTALL GRAY LOCKNUT 5 Install GRAY LOCKNUT 1 onto DRAIN BODY 2 from below SINK Fig A Note The flat side of the GRAY LOCKNUT 1 must face up Tighten firmly by hand No tools are required Check DRAIN FLANGE ...

Page 3: ...open and close properly then refer to the troubleshooting section of these instructions CHECK OPERATION OF POP UP 7 1 1 4 O D Fig B 1 2 PIPE THREAD 2 1 Connect water supply to FAUCET 1 with 1 2 IPS FLEXIBLE SUPPLIES 2 or 3 8 O D BULL NOSE RISERS 3 Use adjustable wrench to tighten connections Do not over tighten Be careful not to kink copper supply when bending Use tubing cutter to cut to proper le...

Page 4: ... if necessary 90 To change direction of handle Turn valve to OFF position Pull HANDLE ASSEMBLY 1 UP firmly to release from ADAPTER 2 Remove ADAPTER SCREW 3 from ADAPTOR 2 Pull off ADAPTER 2 Remove SPRING CLIP 4 Lift STOP WASHER 5 turn 90 and replace Replace SPRING CLIP 4 Replace ADAPTER 2 and ADAPTER SCREW 3 Find correct position of HANDLE ASSEMBLY 1 by adjusting male teeth on ADAPTER 2 to female ...

Page 5: ...lowly Follow CABLE ADJUSTMENT PROCEDURE If you need to remove the Stopper Follow STOPPER REMOVAL PROCEDURE If you would like the ability to remove your Stopper simply by lifting it out of the drain Follow STOPPER INSTALLATION PROCEDURE for Unlocked mode Fig A Fig B REMOVE CAM CAP REMOVE CAM Fig D Fig E Disconnect the Cable from the Drain by threading the Cable Connector 1 counter clockwise Fig A L...

Page 6: ...ked Mode Look at the Plastic Loop at the bottom of the Stopper and notice that the Loop is on one side of the Stopper Fig H To install the stopper in Unlocked mode insert the Stopper into the Drain so that the Plastic Loop is facing toward the front of the Sink and the American Standard logo is facing rear Rotate Stopper slightly if necessary so that the Stopper slides all the way down Fig H Re in...

Page 7: ...ls METAL OR PLASTIC TWO PIECE DRAIN BODY METAL DRAIN BODY WITH PLASTIC TAILPIECE PLASTIC DRAIN BODY WITH PLASTIC TAILPIECE UNTHREAD FLANGE STOPPER WHEN DRAIN IS REMOVED FROM ABOVE SINK WHEN DRAIN IS REMOVED FROM BELOW SINK MOUNTING NUT MOUNTING NUT and GASKET METAL DRAIN BODY PLASTIC DRAIN BODY PLASTIC TAILPIECE P TRAP HALF PIVOT ROD NUT PIVOT ROD NUT SINK STOPPER SCREWDRIVER STOPPER MOUNTING NUT ...

Reviews: