SERVICE
To remove or replace cartidge:
Fig.
A.
Turn valve to OFF position.
Remove HANDLE SCREW
(2)
.
Pull off HANDLE
(3)
and CAP
(4)
.
Unthread CARTRIDGE NUT
(5)
and remove.
Pull out CARTEIDGE
(6)
.
Inspect CARTRIDGE
(6)
and O-RING
(7)
for debris and clean
if necessary.
Clean MANIFOLD
(8)
and rinse clean.
Reinstall CARTRIDGE
(6)
and O-RING
(7)
onto MANIFLOD
(8)
.
Reinstall CARTRIDGE NUT
(5)
, CAP
(4)
and HANDLE ASSEMBLY
(3)
.
If spout drips, operate handle several times from OFF to ON and HOT to
COLD position. Do not force - handles turn only 90˚.
Turn off hot and cold water
supplies before beginning.
CAUTION
2
TEST INSTALLED FITTING
With HANDLE
(1)
in OFF position, turn on WATER
SUPPLIES
(2)
and check all connections for leaks.
Remove AERATOR
(3)
.
Operate HANDLE
(1)
to flush water lines thoroughly.
Replace AERATOR
(3)
.
5
4
2
CHECK DRAIN CONNECTIONS
Operate POP-UP KNOB
(4)
and fill lavatory with water.
Check that DRAIN STOPPER
(5)
makes a good seal
and retains water in SINK. If DRAIN STOPPER
(5)
does not seal properly, please refer to Troubleshooting
section in these instructions.
Release POP-UP KNOB
(4)
down and check all drain
connections and "P" trap for leaks. Tighten
if necessary.
10
“P” TRAP
WASTE
OUTLET
3
1
2
2.5mm HEX KEY
INDEX
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.
CARE INSTRUCTIONS:
8
5
6
7
REMOVE
INSTALL
4
OFF
ON
COLD
HOT