M 9 6 8 8 0 9
Rev. 1. 7
FOR AC-VERSION
(MULTI HOOK-UP); Fig. 3, 3a, 3b
3
NOTE: For AC installation see “AC VERSION; Fig. 2b.”
Make power supply connection before mounting
ENCLOSURE (1) to wall.
1.
Remove COVERS from all ENCLOSURES
(2)
.
Fig. 3.
2.
Remove SOLID BLACK INSERT
(5)
from left side of all
ENCLOSURES
(2)
, except from
Unit #1.
Replace with
GRAY GROMMET
(9).
(Supplied with each Faucet).
Fig. 3.
3. All Units:
Connect the two 27" EXTENSION CABLES
(4)
to the Faucet Sensor Cables. Feed the 27"
EXTENSION CABLE CONNECTORS
(1, 1a)
from the
Faucet
through the top of ENCLOSURE
(2)
.
Fig. 3a.
4.
Connect one 27" EXTENSION CABLE
(1)
to the
SOLENOID
(3).
Fig. 3, 3a.
Connect the second 27"
EXTENSION CABLE
(1a)
to the top of the
Y-CONNECTOR
(8).
5.
Connect the 10 ft. EXTENSION CABLE
(6)
to the top of
the Y-CONNECTOR
(8).
Feed the other end through the
two GRAY GROMMETS
(9)
and connect
to the bottom of
the next Y-CONNECTOR
(8).
Place Y-CONNECTOR
(8)
into
ENCLOSURE
(2)
as shown
Fig. 3a, 3b.
6.
Repeat Steps above for each additional
Unit
, for a Max.
of 15
Units
on one POWER SUPPLY
(7)
.
Fig. 3.
7.
Replace ENCLOSURE COVERS. Tighten cover screws
firmly.
6
Unit #1
Unit #1
Unit #2
Unit #3
Fig. 3
Fig. 3a
1a
8
6
AC
POWER SUPPLY
AC
POWER
SUPPLY
10 ft. EXTENSION
CABLE
10 ft. EXTENSION
CABLE
FAUCET WIRE
CONNECTORS
4
SENSOR
CABLES
3
7
2
1
5
5
6
6
6
8
8
9
5
9
FAUCET WIRE
CONNECTORS
FAUCET WIRE
CONNECTORS
6
6
8
9
Fig. 3b
*MAXIMUM OF 15 UNITS PER AC POWER SUPPLY.
10' MAXIMUM CABLE LENGTH BETWEEN UNITS.