background image

M 9 6 8 8 0 9

 

Rev. 1. 7

    FOR AC-VERSION

(MULTI HOOK-UP); Fig. 3, 3a, 3b

3

NOTE: For AC installation see “AC VERSION; Fig. 2b.”

Make power supply connection before mounting 

ENCLOSURE (1) to wall.

1.

 Remove  COVERS from all ENCLOSURES 

(2)

Fig. 3.

2.

 Remove SOLID BLACK INSERT 

(5)

 from left side of all 

ENCLOSURES 

(2)

, except from 

Unit #1. 

Replace with 

GRAY GROMMET 

(9). 

(Supplied with each Faucet). 

Fig. 3.

3. All Units: 

Connect the two 27" EXTENSION CABLES 

(4) 

to the Faucet Sensor Cables. Feed the 27" 

EXTENSION CABLE CONNECTORS 

(1, 1a) 

from the 

Faucet

 

through the top of ENCLOSURE 

(2)

Fig. 3a.

4. 

Connect one 27" EXTENSION CABLE 

(1)

 to the 

SOLENOID 

(3).

 

Fig. 3, 3a. 

Connect the second 27" 

EXTENSION CABLE 

(1a)

 to the top of the 

Y-CONNECTOR

 (8).

5. 

Connect the 10 ft. EXTENSION CABLE 

(6)

 to the top of 

the Y-CONNECTOR 

(8).

 Feed the other end through the 

two GRAY GROMMETS 

(9) 

and connect

 

to the bottom of 

the next Y-CONNECTOR 

(8).

 Place Y-CONNECTOR 

(8) 

into

 

ENCLOSURE 

(2) 

as shown

 Fig. 3a, 3b.

  

 

6. 

Repeat Steps above for each additional 

Unit

, for a Max. 

of 15 

Units

 on one POWER SUPPLY 

(7)

Fig. 3.

7. 

Replace ENCLOSURE COVERS. Tighten cover screws 

firmly. 

6

Unit #1

Unit #1

Unit #2

Unit #3

Fig. 3

Fig. 3a

1a

8

6

AC 

POWER SUPPLY

AC 

POWER

SUPPLY

10 ft. EXTENSION

CABLE

10 ft. EXTENSION

CABLE

FAUCET WIRE

CONNECTORS

  4

SENSOR

CABLES

3

7

2

1

5

5

6

6

6

8

8

9

5

9

FAUCET WIRE

CONNECTORS

FAUCET WIRE

CONNECTORS

6

6

8

9

Fig. 3b

*MAXIMUM OF 15 UNITS PER AC POWER SUPPLY.

10' MAXIMUM CABLE LENGTH BETWEEN UNITS.

Summary of Contents for Selectronic 6055.102

Page 1: ...ve this manual to the customer after installation In Toronto Area only 1 905 3061093 Product No s Options Specifications How to Install Electrical Hook up Maintenance FAQ s Replacement Parts 1 2 2 3 4...

Page 2: ...u begin UNPACKING How to order the Selectronic Product 1 Choose Power Supply 2 Choose Desired Spout Single Hole Sink Single Inlet 1 and 3 Hole Sinks Single Inlet 1 and 3 Hole Sinks Hot and Cold Inlets...

Page 3: ...ION Use only American Standard supplied cable sets Using non AS supplied cables or cutting splicing or modifying any components will void the warranty Note All plumbing and electrical wiring must be i...

Page 4: ...nting surface 1524mm 60 14 356mm 3 3 4 96mm 2 3 4 71mm 3 76mm 21 mm 2 4 3 1 1 1 20 500mm MOUNTING HOLES SUPPLIES WASTE ENCLOSURE MOUNTING HOLES LAVATORY RIM OR MOUNTING SURFACE 3 NOTE If using Mixing...

Page 5: ...NNECTOR 5a through GROMMET 6 as shown Fig 1c 5 Connect SOLENOID CABLE 7 and BATTERY CONNECTOR 5a to EXTENSION CABLES 2 from Faucet Sensor Fig 1d 6 Replace ENCLOSURE COVER 1 Tighten cover screws firmly...

Page 6: ...OSURE 3 Fig 2a 3 Remove SPLIT PLUG 4 from POWER SUPPLY GROMMET 5 Insert POWER CORD 7 into SPLIT PLUG 4 Insert POWER CORD CONNECTOR 6 through POWER SUPPLY GROMMET 5 Push SPLIT PLUG 4 into POWER SUPPLY...

Page 7: ...3 3a Connect the second 27 EXTENSION CABLE 1a to the top of the Y CONNECTOR 8 5 Connect the 10 ft EXTENSION CABLE 6 to the top of the Y CONNECTOR 8 Feed the other end through the two GRAY GROMMETS 9...

Page 8: ...e BATTERY HOLDER 4 Fig 3 3 Replace ENCLOSURE COVER Tighten cover screws firmly Fig 3 HOW TO INSTALL AND CHANGE BATTERY Fig 3 3 1 Setting the Detection Zone Distance Remove cover from ENCLOSURE Disconn...

Page 9: ...tighten with a 7 16 socket Caution do not over tighten strainer Note It is recommended to clean strainer every 6 months 6 Open SUPPLY STOP 1 with 4mm Hex wrench 7 Replace ENCLOSURE COVER Tighten cover...

Page 10: ...sensor range but turns off when in sensor range A Sensor wires to solenoid are reversed Q What is the normal operating pressure range A Faucet will operate with supply pressures ranging from 20 80 ps...

Page 11: ...BATTERY DEAD BATTERY INSTALL NEW BATTERY REPEAT NO CHECK FOR DAMANGE IN SENSOR WIRE REPLACE SENSOR ONLY IF ABSOLUTELY NEEDED ARE EXTERNAL SUPPLY STOPS OPEN IS INTERNAL SUPPLY STOP OPEN REPEATED DOUBL...

Page 12: ...24162 0070A SUPPLY HOSE 044912 0070A MOUNTING NUT M964904 0070A SENSOR KIT M922887 YYY0A 1 5 GPM AERATOR M922286 YYY0A 0 35 GPM AERATOR 6055 104 6056 104 066508 YYY0A 0 5 GPM AERATOR PRODUCT NUMBERS C...

Reviews: