American Standard QR031 Owner'S Manual Download Page 2

 2
 

Table of Contents

Table of Contents    .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 2

Safety Information  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 2

Warranty    .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 4

One Year Limited Warranty  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 4
Warranty Claim Procedure   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 4

Pre-Installation  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 5

Tools Required   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 5
Hardware Included  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 5
Package Contents    .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 6
Planning Installation    .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 7

Installation  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 10

Operation  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 13

Maintenance    .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 14

Baffle Filters    .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 14
Light Bulbs  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 14

Care and Cleaning  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 15

Range Hood   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 15
Baffle Filters    .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 15

Troubleshooting    .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 16

Specifications  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 17

Wiring Diagram    .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 17

Service Parts    .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 18

Safety Information

READ AND SAVE THESE INSTRUCTNIONS
Warning - To reduce the risk of fire, electric shock, or injury to 

persons, observe the following:

1 .  Use this unit only in the manner intended by the manufacturer . If 

you have any questions, contact the manufacturer .

2 .  Before servicing or cleaning unit, switch power off at service 

panel and lock service disconnecting means to prevent 
power from being switched on accidentally . When the service 
disconnecting means cannot be locked, securely fasten a 
prominent warning device, such as a tag, to the service panel .

3 .  Installation work and electrical wiring must be done by qualified 

person(s) in accordance with all applicable codes and standards, 
including fire-rated construction .

4 .  Sufficient air is needed for proper combustion and exhausting 

of gases through the flue (chimney) of fuel burning equipment 
to prevent back drafting . Follow the heating equipment 
manufacturer's guideline and safety standards such as those 
published by the National Fire Protection Association (NFPA) 
and the American Society for Heating, Refrigeration and Air 
Conditioning Engineers (ASHRAE), and the local code authorities .

5 .  When cutting or drilling into wall or ceiling, do not damage 

electrical wiring and other hidden utilities .

6 .  Ducted fans must always be vented to the outdoors .

DANGER: 

Turn off the power circuit breaker or the power 

switch on the junction box before installing or servicing 
this unit . Touching circuitry inside the range hood while it is 
energized will result in death or serious injury .

DANGER: 

All electrical wiring must be properly installed, 

insulated, and grounded . Improper insulation and grounding 
will result in deadly electrical shock .

DANGER: 

If installing this unit over a gas range, turn off 

the gas at the source before installing or servicing this unit .

WARNING: 

Attempting to install or service this unit 

when you do not have the necessary technical or electrical 
background could result in personal injury .

WARNING: 

This unit has sharp edges . Always wear safety 

gloves during installation, cleaning, or servicing .

WARNING: 

Always leave safety grills and filters in place . 

Without these components, operating fans could catch on to 
hair, fingers, or loose clothing .

WARNING: 

Stay clear of the rotating fan when the motor 

is running . 

WARNING: 

Keep this appliance clean and free of grease 

and residue build-up at all times to prevent fires . 

CAUTION: 

This device is for general ventilating use only . 

Do not use to exhaust hazardous or explosive materials and 
vapors . 

Summary of Contents for QR031

Page 1: ...d the benchmark of fine quality for over 100 years To ensure that your installation proceeds smoothly please read these instructions carefully before you begin Stainless Steel Chimney Range Hood THANK...

Page 2: ...fety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code auth...

Page 3: ...rn off the burner If the flames do not go out immediately evacuate and call the fire department Never pick up a flaming pan Do not use water including wet dishcloths or towels as you could cause a ste...

Page 4: ...rred for labour or materials removal and installation of replacement units or any other incidental or consequential damages Costs relating to obtaining access for repair or replacement are the respons...

Page 5: ...knife Marker or pencil Duct tape Adjustable wrench Phillips screwdriver Flathead screwdriver Electric drill or powered screwdriver Safety goggles Safety gloves HARDWARE INCLUDED NOTE Hardware not show...

Page 6: ...nued PACKAGE CONTENTS B C D E Part Description Quantity A Range hood including pre installed controls lights blower baffle filters and damper 1 B Lower chimney 1 C Upper chimney 1 D Hood bracket 2 E C...

Page 7: ...from the cooking surface to the range hood is 18 in 458 mm for electric ranges and 29 5 in 750 mm for gas ranges If your gas range specifies a different distance use the greater distance of the two T...

Page 8: ...with elbows and transitions will reduce the performance of the range hood Use as few of them as possible Use round metal duct work with a uniform diameter of 6 in 152 mm Larger ducting may be require...

Page 9: ...wood must be sanded until smooth A hole through metal must have a grommet 8 When cutting or drilling into the wall or ceilling do not damage electrical wiring and other hidden utilities 9 Wire size mu...

Page 10: ...e holes in the bracket E Place the hood brackets D on the wall aligning their center notches 11 2 in 284 mm above the horizontal line 2 and 5 36 in 136 mm apart Mark the wall at the center of the hole...

Page 11: ...d re install it if necessary Insert one end of the damper 3 into the hinge slot 4 at the top of the range hood A Gently bend the damper 3 and insert its other end into the hinge slot 4 5 Installing th...

Page 12: ...chimney extensions B C and place them on the floor Lower the upper chimney C onto the lower chimney B You should now have both chimney extensions together as one unit Place the chimney onto the range...

Page 13: ...ing down Once the countdown is completed the range hood will beep the fan and lights will turn off automatically and the clock will show in the screen During the countdown operation You will still be...

Page 14: ...them with similar baffle filters with stainless steel clips Also replace damaged baffle filters with punctures bends or broken frames Turn off the range hood and disconnect the power Replace with an e...

Page 15: ...teriorate the surface rapidly Do not allow cleaning compounds salt solutions disinfectants or bleaches to remain in contact with the product for extended periods of time Do not allow deposits to remai...

Page 16: ...g The thermal protection system detects if the motor is too hot to operate and shuts the motor down In this case the motor will function properly after the thermal protection system cools down after a...

Page 17: ...ey 8 74 in W x 8 82 in D x 24 02 in H 222 mm W x 224 mm D x 610 mm H Upper Chimney 8 66 in W x 8 74 in D x 24 02 in H 220 mm W x 222 mm D x 610 mm H WIRING DIAGRAM 29 5 in 750 mm 8 7 in 222 mm 8 7 in...

Page 18: ...art s and have the part description s ready C D E F A B G AA BB CC Part Description Code Quantity Part Description Code Quantity A Control board QHR142 1 AA Toggle bolt QHR133 4 B Control panel QHR143...

Page 19: ...Questions problems missing parts Before returning to the store call Customer Service 8 30 a m 5 p m EST Monday Friday 1 877 333 0098 CONGLOM COM Retain this manual for future use...

Reviews: