Installation 

Drilling the pilot holes

 

- Draw a vertical line (1) on the supporting wall up to the 

ceiling, or as high as practical, at the center of the area in 
which the hood will be installed .

 

- Draw a horizontal line (2) at 18 in . (458 mm) above an 

electric stove or 29 .5 in . (750 mm) above a gas stove .

 

- Place the chimney support bracket (E) on the wall about 

0 .8 in . (20 mm) from the ceiling or upper limit, aligning the 
center notch with the vertical reference line (1) . Mark the 
wall at the center of the holes in the bracket (E) .

 

- Place the hood brackets (D) on the wall, aligning their 

center notches 11 .2 in . (284 mm) above the horizontal line 
(2) and 5 .36 in . (136 mm) apart . Mark the wall at the center 
of the holes in the bracket . 

 

- Drill pilot holes at the marked locations .

Installing the toggle bolts and 

chimney support bracket

 

- Screw the four toggle bolts (DD) into the wall, leaving the 

head of the bolts approximately 0 .25 in . (6 .4 mm) away 
from the wall surface .

 

- Place the chimney support bracket (E) over the upper 

toggle bolts (DD) . Tighten securely .

Attaching the hood brackets

 

- Attach the two hood brackets (D) to the back of the range 

hood (A) with the four screws (AA) and washers (BB) .

A

AA

BB

D

A

3

4

3

Wall

Summary of Contents for QR031

Page 1: ...d the benchmark of fine quality for over 100 years To ensure that your installation proceeds smoothly please read these instructions carefully before you begin Stainless Steel Chimney Range Hood THANK...

Page 2: ...fety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code auth...

Page 3: ...rn off the burner If the flames do not go out immediately evacuate and call the fire department Never pick up a flaming pan Do not use water including wet dishcloths or towels as you could cause a ste...

Page 4: ...rred for labour or materials removal and installation of replacement units or any other incidental or consequential damages Costs relating to obtaining access for repair or replacement are the respons...

Page 5: ...knife Marker or pencil Duct tape Adjustable wrench Phillips screwdriver Flathead screwdriver Electric drill or powered screwdriver Safety goggles Safety gloves HARDWARE INCLUDED NOTE Hardware not show...

Page 6: ...nued PACKAGE CONTENTS B C D E Part Description Quantity A Range hood including pre installed controls lights blower baffle filters and damper 1 B Lower chimney 1 C Upper chimney 1 D Hood bracket 2 E C...

Page 7: ...from the cooking surface to the range hood is 18 in 458 mm for electric ranges and 29 5 in 750 mm for gas ranges If your gas range specifies a different distance use the greater distance of the two T...

Page 8: ...with elbows and transitions will reduce the performance of the range hood Use as few of them as possible Use round metal duct work with a uniform diameter of 6 in 152 mm Larger ducting may be require...

Page 9: ...wood must be sanded until smooth A hole through metal must have a grommet 8 When cutting or drilling into the wall or ceilling do not damage electrical wiring and other hidden utilities 9 Wire size mu...

Page 10: ...e holes in the bracket E Place the hood brackets D on the wall aligning their center notches 11 2 in 284 mm above the horizontal line 2 and 5 36 in 136 mm apart Mark the wall at the center of the hole...

Page 11: ...d re install it if necessary Insert one end of the damper 3 into the hinge slot 4 at the top of the range hood A Gently bend the damper 3 and insert its other end into the hinge slot 4 5 Installing th...

Page 12: ...chimney extensions B C and place them on the floor Lower the upper chimney C onto the lower chimney B You should now have both chimney extensions together as one unit Place the chimney onto the range...

Page 13: ...ing down Once the countdown is completed the range hood will beep the fan and lights will turn off automatically and the clock will show in the screen During the countdown operation You will still be...

Page 14: ...them with similar baffle filters with stainless steel clips Also replace damaged baffle filters with punctures bends or broken frames Turn off the range hood and disconnect the power Replace with an e...

Page 15: ...teriorate the surface rapidly Do not allow cleaning compounds salt solutions disinfectants or bleaches to remain in contact with the product for extended periods of time Do not allow deposits to remai...

Page 16: ...g The thermal protection system detects if the motor is too hot to operate and shuts the motor down In this case the motor will function properly after the thermal protection system cools down after a...

Page 17: ...ey 8 74 in W x 8 82 in D x 24 02 in H 222 mm W x 224 mm D x 610 mm H Upper Chimney 8 66 in W x 8 74 in D x 24 02 in H 220 mm W x 222 mm D x 610 mm H WIRING DIAGRAM 29 5 in 750 mm 8 7 in 222 mm 8 7 in...

Page 18: ...art s and have the part description s ready C D E F A B G AA BB CC Part Description Code Quantity Part Description Code Quantity A Control board QHR142 1 AA Toggle bolt QHR133 4 B Control panel QHR143...

Page 19: ...Questions problems missing parts Before returning to the store call Customer Service 8 30 a m 5 p m EST Monday Friday 1 877 333 0098 CONGLOM COM Retain this manual for future use...

Reviews: