background image

M968851 Rev.1.3

Operate LIFT KNOB 

(1)

 to verify that STOPPER 

(2) 

opens and

closes.

Note: 

If STOPPER 

(2)

 does not open and close properly then refer

to the “troubleshooting section” of these instructions.

CHECK OPERATION OF POP-UP

8

MAKE WATER SUPPLY AND WASTE CONNECTIONS

9

Thread CABLE CONNECTOR 

(1) 

clockwise

onto DRAIN BODY CONNECTION 

(2)

 and

hand tighten. 

Fig.

 

A.

Your new POP-UP DRAIN installation is
now complete. 

Fig.

 

B.

Note: 

Tailpeice on pop-up drain is 1-1/4” O.D.

Fig.

 

B.

ATTACH CABLE CONNECTOR

7

3

1

APPROX. 20

"

2

COLD

HOT

3/8" COMPRESSION

RED
BAND

BLUE
BAND

Connect FLEXIBLE SUPPLIES 

(1, 2)

 directly to wall supplies.

Connection on fitting supplies are 3/8" compression. Connect
left SUPPLY 

(1)

 to Hot (Marked with a Red Band) and right supply

to COLD 

(2)

 wall supply.

Faucet supplies are 20" long from faucet base.

Note: If additional supply length is required, installer must
purchase additional parts separately.

Important: If SUPPLY HOSES 

(1, 2)

 are to long, loop as

illustrated to avoid kinking.

Connect 1-1/4” O.D. tailpiece on POP-UP DRAIN to

waste outlet.

Fig.

 

A.

Fig.

 

B.

1-1/4” O.D.

1

2

2

1

Summary of Contents for MONOBLOCK BIDET 2064.011

Page 1: ...e From below push GASKET 7 and RETAINING WASHER 5 onto MOUNTING STUD 4 Secure Faucet with MOUNTING NUT 6 pulling faucet to front of sink so SUPPLIES 3 rests against mounting hole Before final tightening make sure collar on MOUNTING NUT 6 is seated into RETAINING WASHER 5 Figure B Adjust Faucet so that it is centered Tighten MOUNTING NUT 6 to complete faucet mounting Figure A Figure B To ensure tha...

Page 2: ...mly with Adjustable Wrench or Channel Locks 2 INSTALL DRAIN FROM BELOW FIXTURE 5 From under side of BIDET install DRAIN BODY 1 up through drain outlet Note No plumber s putty or caulk is required The CABLE ATTACHMENT POINT 2 must face towards the rear of the BIDET DRAIN OUTLET Install FOAM GASKET 3 and FLANGE 4 onto drain body from above BIDET and tighten FLANGE 4 firmly 1 4 3 4 Fig A Fig B Fig A ...

Page 3: ... pop up drain is 1 1 4 O D Fig B ATTACH CABLE CONNECTOR 7 3 1 APPROX 20 2 COLD HOT 3 8 COMPRESSION RED BAND BLUE BAND Connect FLEXIBLE SUPPLIES 1 2 directly to wall supplies Connection on fitting supplies are 3 8 compression Connect left SUPPLY 1 to Hot Marked with a Red Band and right supply to COLD 2 wall supply Faucet supplies are 20 long from faucet base Note If additional supply length is req...

Page 4: ...D 5 P TRAP WASTE OUTLET 2 2 4 SERVICE To remove or replace cartidge Turn valve to OFF position Pull out PLUG BUTTON 1 and remove HANDLE SCREW 2 Pull off HANDLE 3 and CAP 4 Unthread CARTRIDGE NUT 5 and remove Pull out CARTEIDGE 6 Inspect CARTRIDGE 6 and O RINGS 7 for debris and clean if necessary Clean MANIFOLD 8 and rinse clean Reinstall CARTRIDGE 6 and O RINGS 7 onto MANIFLOD 8 Reinstall CARTRIDG...

Page 5: ...llow CABLE ADJUSTMENT PROCEDURE If you need to remove the Stopper Follow STOPPER REMOVAL PROCEDURE If you would like the ability to remove your Stopper simply by lifting it out of the drain Follow STOPPER INSTALLATION PROCEDURE for Unlocked mode Fig B Fig A REMOVE CAM Fig E Disconnect the Cable from the Drain by threading the Cable Connector 1 counter clockwise Fig A Look at the area on the Drain ...

Page 6: ...k at the Plastic Loop at the bottom of the Stopper and notice that the Loop is on one side of the Stopper Fig H To install the stopper in Unlocked mode insert the Stopper into the Drain so that the Plastic Loop is facing toward the front of the Sink and the American Standard logo is facing rear Rotate Stopper slightly if necessary so that the Stopper slides all the way down Fig H Re install the Ca...

Reviews: