background image

4

754063-100 Rev. B

ELLISSE OVAL 

MODEL 2709 AIR BATH

C/L

FOR SPOUT

& VALVES

FOR HAND

SPRAY

FITTINGS

DECK

EDGE OF

FITTINGS

DECK

35-3/4

(908mm)

TO END OF TUB

1-1/2

(38mm)

1-1/2

(38mm)

1-1/2

(38mm)

2-1/2

(64mm)

4-1/2

(114mm)

4-1/2

(114mm)

5

(127mm)

DRAIN

ROUGHING-IN REFERENCES

HOLE DRILLING LOCATION FOR AMERICAN STANDARD "TOWN SQUARE" 

DECK MOUNT BATH FILLER WITH PERSONAL SHOWER, MODEL #2555.901 ONLY

C/L

FOR SPOUT

& VALVES

FOR HAND

SPRAY

FITTINGS

DECK

EDGE OF

FITTINGS

DECK

29-3/4

(755mm)

TO END OF TUB

1-1/2

(38mm)

1-1/2

(38mm)

1-1/2

(38mm)

2-1/2

(64mm)

4-1/2

(114mm)

4-1/2

(114mm)

5

(127mm)

DRAIN

HOLE DRILLING LOCATION FOR AMERICAN STANDARD "TOWN SQUARE" 

DECK MOUNT BATH FILLER WITH PERSONAL SHOWER, MODEL #2555.901 ONLY

TOP VIEW

 TOWN SQUARE

®

 5' x 42" 

MODEL 2748 AIR BATH

59-1/2"

(1511mm)

 INTEGRAL

 FITTING DECK

 2-1/2" X 14"

(64 X 356mm)

29-3/4"

(755mm)

41-5/8"

(1057mm)

CONTROL

PANEL

OUTLINE OF CUTOUT

 58" X 40-1/8"

(1473 X 1019mm)

PROVIDE ACCESS TO BLOWER FOR

SERVICE ON ALL INSTALLATIONS 

C/L OF

DRAIN

OUTLET

FLOOR CUTOUT

9" X 18"

(229 X 458mm)

3/4"

(19mm)

14-1/2"

(368mm)

 5-1/4"

(133mm)

3"

(76mm)

OUTLINE OF SKID

RESISTANT SURFACE

20 AIR JETS

EDGE OF

FLOOR

CUTOUT

AIR 

BLOWER

LEVELING STRINGER

(NOT FOR SUPPORT)

1-1/2" N.P.T. THREADS

2"

(51mm)

5-3/4"

(146mm)

C/L OF

OVERFLOW

21"

(533mm)

23"

(584mm)

ROUGH

FLOOR

INTEGRAL FEET WITH

ATTACHED BASEBOARD

1-1/2" O.D. TAILPIECE

 3/4"

(19mm)

3-1/8" 

(79mm)

AIR

BLOWER

7-3/4" TYPICAL

(197mm)

10-1/4"

(260mm)

END VIEW

END VIEW

TOP VIEW

CONTROL

PANEL

41-3/4"

(1060mm)

26-3/4

(679mm)

7-3/4” TYPICAL

(197mm)

OUTLINE OF SKID

RESISTANT SURFACE

35-3/4"

(908mm)

13-1/4"

(337mm)

4"

(102mm)

71-1/2"

(1816mm)

3"

(76mm)

FLOOR CUTOUT

9" X 19"

(229 X 459mm)

OUTLINE OF CUTOUT

70" X 40-1/4" (1778 X 1022mm)

PROVIDE ACCESS

TO BLOWER FOR

SERVICE ON ALL

INSTALLATIONS 

 INTEGRAL

 FITTING DECK

 2-1/4" X 14"

(57 X 356mm)

3/4"

(19mm)

EDGE OF

FLOOR

CUTOUT

AIR BLOWER

C/L OF

DRAIN

OUTLET

20 AIR JETS

LEVELING STRINGER

(NOT FOR SUPPORT)

1-1/2" N.P.T. THREADS

2"

(51mm)

3-1/4"

(83mm)

C/L OF

OVERFLOW

20"

(508mm)

22"

(559mm)

ROUGH

FLOOR

1-1/2" O.D.TAILPIECE

5/8"

(16mm)

 3"

(76mm)

AIR BLOWER

10-1/4”

(260mm)

INTEGRAL FEET WITH

ATTACHED BASEBOARD

TOP VIEW

END VIEW

TOP VIEW

END VIEW

FLOOR CUTOUT

229 X 459mm

(9" X 19")

1759 mm

(69-1/4")

OUTLINE OF

CUTOUT

240 mm

(9-7/16")

978 mm

(38-1/2")

489mm

(19-1/4")

76mm

(3")

CL OF DRAIN

OUTLET

PROVIDE ACCESS

TO BLOWER FOR

SERVICING ON ALL

INSTALLATIONS

16 AIR JETS

AIR

BLOWER

SEE FTTG.SPECS

FOR DIMENSION

CLOF SUPPLIES

CONTROL

PANEL

11-1/4"

(286mm)

7-3/4" TYPICAL

(197mm)

ROUGH 

FLOOR

1-1/2" O.D. TAILPIECE

495mm

(19-1/2")

INTEGRAL FEET 

WITH ATTACHED 

BASEBOARD 

86mm (3-3/8")

38mm

(1-1/2")

533mm

(21")

1-1/2" N.P.T.M. THREADS

35mm 

(1-3/8")

98mm

(3-7/8")

CL TO OVERFLOW

 TOWN SQUARE

®

 6' x 42" 

MODEL 2742 AIR BATH

 GREEN TEA™ 5' x 36" 

MODEL 3571 AIR BATH

LEVELING STRINGER NOT 

FOR SUPPORT 

60

(1524mm)

36

(914mm)

11-1/2

(292mm)

OUTLINE OF CUTOUT 58.5 x 34.5 (1486 x 876mm)

14-3/4

(375mm)

CONTROL

PANEL

BLOWER

CUTOUT IN FLOOR FOR DRAIN

20 AIR JETS

9

(229mm)

CL

PROVIDE ACCESS TO BLOWER FOR 

SERVICE ON ALL INSTALLATIONS

ROUGH 

FLOOR

1-1/2" O.D. TAILPIECE

508mm

(20")

INTEGRAL FEET 

WITH ATTACHED 

BASEBOARD 

51mm

(2")

559mm

(22")

1-1/2" N.P.T.M. THREADS

35mm 

(1-3/8")

98mm

(3-7/8")

CL TO OVERFLOW

102mm (4")

Summary of Contents for Ellisse 2709

Page 1: ...em To insure maximum performance and pleasure from this product please follow the instructions and cautions AS America Inc 00 All product names listed herein are trademarks of AS America Inc unless ot...

Page 2: ...ge Safety Instructions Notice Page 3 Roughing in Reference Page 4 6 Installation and Framing Instructions Page 7 Supplied Drain Assembly and Installation Instructions Page 13 Post Installation Instruc...

Page 3: ...ges can cause drowsiness or hyperthermia resulting in loss of consciousness or even drowning WARNING Pregnancy If you are or think you may be pregnant consult your physician before using the bathtub U...

Page 4: ...6 3 4 679mm 7 3 4 TYPICAL 197mm OUTLINE OF SKID RESISTANT SURFACE 35 3 4 908mm 13 1 4 337mm 4 102mm 71 1 2 1816mm 3 76mm FLOOR CUTOUT 9 X 19 229 X 459mm OUTLINE OF CUTOUT 70 X 40 1 4 1778 X 1022mm PRO...

Page 5: ...GH FLOOR 1 1 2 O D TAILPIECE 508mm 20 INTEGRAL FEET WITH ATTACHED BASEBOARD 51mm 2 559mm 22 1 1 2 N P T M THREADS 35mm 1 3 8 98mm 3 7 8 C L TO OVERFLOW 102mm 4 PROVIDE ACCESS TO BLOWER FOR SERVICE ON...

Page 6: ...l 223 L 44 Gal 167 L 19 x 49 In 483mm x 1245mm 54 1 2 x 27 In 1384mm x 686mm 14 In 356mm 36 Lbs Sq Ft 175 Kgs Sq m 25 6 45 1 GENERAL SPECIFICATIONS FOR 3572 AIR BATH SYSTEM INSTALLED SIZE WEIGHT WEIGH...

Page 7: ...the air massage system according to the enclosed drain installation instructions Before replacing your air bath for final installation be certain that an opening has been provided in the sub floor for...

Page 8: ...AL DIAGRAM READ AND FOLLOW ALL INSTRUCTIONS WIRE SELECTION GUIDE Maximum distance from fusebox to motor The sizes shown on this chart are recommendations for copper conductors only Always follow local...

Page 9: ...per installation instructions provided with the tub Bath deck support material Bathtub Waterproof Sealant UNDER DECK MOUNTING INSTRUCTIONS DRAIN STOPPER WITH ADJUSTABLE BOLT METAL STRAINER BOLT METAL...

Page 10: ...ed dabs of 100 silicone sealant to bottom waste drain flange and press flat rubber gasket into place as shown in photos B and C 6 Apply 1 continuous bead of 100 silicone sealant to flat rubber gasket...

Page 11: ...EN Carefully remove excess silicone from acrylic surface as directed by silicone sealant directions 9 From unit back side overflow nut should be in alignment with overflow opening as shown in photo F...

Page 12: ...o M 14 Test fit and trim pipe as required to get overflow drain into center of overflow hole BEFORE GLUING vertical pipe into 0 degree elbow as shown in photos N 1 and N 2 15 Apply PVC cement to Verti...

Page 13: ...ns and closes drain 21 Place drain stopper into drain waste hole as shown in photo T 22 The drain stopper should prevent water from draining out of tub when the escutcheon is in the fully counterclock...

Page 14: ...infectant spray or concentrate or Lysol Basin Tub and Tile Cleaner Windex Mr Clean Dow Disinfectant Bathroom Cleaner or cleaning products in aerosol cans HARSH CHEMICALS SHOULD NEVER BE USED ON ACRYLI...

Page 15: ...alled in an attic area The blower motor must be located within 1 feet of rigid piping from the bath air manifold This limitation is for the total pipe length and applies to any direction changes and e...

Page 16: ...eterioration through normal wear and tear and the expense of normal maintenance 3 Commercial application 4 Options and accessories American Standard s limited warranty on these items is one year for p...

Reviews: