background image

754063-100 Rev. B

All wiring must be performed by a licensed electrician in accordance with the national electrical code and all other applicable codes.

WARNING: When using electrical products, basic precautions should always be observed, including the following:

1.  DANGER:  RISK OF ELECTRIC SHOCK! Connect only to a circuit protected by a ground-fault circuit interrupter.

2.  Permit access for servicing blower as noted.

3.  All building materials and wiring should be routed away from the air blower. 

AIR MASSAGE SYSTEM

ELECTRICAL INSTALLATION INSTRUCTIONS

ELECTRICAL DIAGRAM

READ AND FOLLOW ALL INSTRUCTIONS

WIRE SELECTION GUIDE

Maximum distance from

fusebox to motor

The sizes shown on this

chart are recommendations

for copper conductors

only.  Always follow

local and national

electrical codes

Motor 

Hi Performance

Rating

2.1 H.P.,

1.4 H.P.,

and 1.25 H.P.

50'

100'

115V Power Line

150'

200'

12

10

8

8

AIR MASSAGE SYSTEM:

The air bath should be installed on a 10 vac, 15 or 0 amp dedicated circuit. The circuit should be hard-wired 
from the electrical power supply panel.  The circuit must be a three (3) wire circuit from the electrical supply panel.
A grounded neutral wire and a third wire, earth ground, are essential.

!

USE 15 OR 20 AMP

GFCI OUTLET

AIR BLOWER

CHROMATHERAPY LIGHT

CONTROL BOX (OPTIONAL)

B

L

A

C

K

W

H

IT

E

120 VAC

GND.

Summary of Contents for Ellisse 2709

Page 1: ...em To insure maximum performance and pleasure from this product please follow the instructions and cautions AS America Inc 00 All product names listed herein are trademarks of AS America Inc unless ot...

Page 2: ...ge Safety Instructions Notice Page 3 Roughing in Reference Page 4 6 Installation and Framing Instructions Page 7 Supplied Drain Assembly and Installation Instructions Page 13 Post Installation Instruc...

Page 3: ...ges can cause drowsiness or hyperthermia resulting in loss of consciousness or even drowning WARNING Pregnancy If you are or think you may be pregnant consult your physician before using the bathtub U...

Page 4: ...6 3 4 679mm 7 3 4 TYPICAL 197mm OUTLINE OF SKID RESISTANT SURFACE 35 3 4 908mm 13 1 4 337mm 4 102mm 71 1 2 1816mm 3 76mm FLOOR CUTOUT 9 X 19 229 X 459mm OUTLINE OF CUTOUT 70 X 40 1 4 1778 X 1022mm PRO...

Page 5: ...GH FLOOR 1 1 2 O D TAILPIECE 508mm 20 INTEGRAL FEET WITH ATTACHED BASEBOARD 51mm 2 559mm 22 1 1 2 N P T M THREADS 35mm 1 3 8 98mm 3 7 8 C L TO OVERFLOW 102mm 4 PROVIDE ACCESS TO BLOWER FOR SERVICE ON...

Page 6: ...l 223 L 44 Gal 167 L 19 x 49 In 483mm x 1245mm 54 1 2 x 27 In 1384mm x 686mm 14 In 356mm 36 Lbs Sq Ft 175 Kgs Sq m 25 6 45 1 GENERAL SPECIFICATIONS FOR 3572 AIR BATH SYSTEM INSTALLED SIZE WEIGHT WEIGH...

Page 7: ...the air massage system according to the enclosed drain installation instructions Before replacing your air bath for final installation be certain that an opening has been provided in the sub floor for...

Page 8: ...AL DIAGRAM READ AND FOLLOW ALL INSTRUCTIONS WIRE SELECTION GUIDE Maximum distance from fusebox to motor The sizes shown on this chart are recommendations for copper conductors only Always follow local...

Page 9: ...per installation instructions provided with the tub Bath deck support material Bathtub Waterproof Sealant UNDER DECK MOUNTING INSTRUCTIONS DRAIN STOPPER WITH ADJUSTABLE BOLT METAL STRAINER BOLT METAL...

Page 10: ...ed dabs of 100 silicone sealant to bottom waste drain flange and press flat rubber gasket into place as shown in photos B and C 6 Apply 1 continuous bead of 100 silicone sealant to flat rubber gasket...

Page 11: ...EN Carefully remove excess silicone from acrylic surface as directed by silicone sealant directions 9 From unit back side overflow nut should be in alignment with overflow opening as shown in photo F...

Page 12: ...o M 14 Test fit and trim pipe as required to get overflow drain into center of overflow hole BEFORE GLUING vertical pipe into 0 degree elbow as shown in photos N 1 and N 2 15 Apply PVC cement to Verti...

Page 13: ...ns and closes drain 21 Place drain stopper into drain waste hole as shown in photo T 22 The drain stopper should prevent water from draining out of tub when the escutcheon is in the fully counterclock...

Page 14: ...infectant spray or concentrate or Lysol Basin Tub and Tile Cleaner Windex Mr Clean Dow Disinfectant Bathroom Cleaner or cleaning products in aerosol cans HARSH CHEMICALS SHOULD NEVER BE USED ON ACRYLI...

Page 15: ...alled in an attic area The blower motor must be located within 1 feet of rigid piping from the bath air manifold This limitation is for the total pipe length and applies to any direction changes and e...

Page 16: ...eterioration through normal wear and tear and the expense of normal maintenance 3 Commercial application 4 Options and accessories American Standard s limited warranty on these items is one year for p...

Reviews: