All wiring must be performed by a licensed electrician in accordance with the national electrical code and all other applicable codes.
WARNING: When using electrical products, basic precautions should always be observed, including the following:
1. DANGER: RISK OF ELECTRIC SHOCK! Connect only to a circuit protected by a ground-fault circuit interrupter.
2. Permit access for servicing blower as noted.
3. All building materials and wiring should be routed away from the air blower.
AIR MASSAGE SYSTEM
ELECTRICAL INSTALLATION INSTRUCTIONS
ELECTRICAL DIAGRAM
READ AND FOLLOW ALL INSTRUCTIONS
WIRE SELECTION GUIDE
Maximum distance from
fusebox to motor
The sizes shown on this
chart are recommendations
for copper conductors
only. Always follow
local and national
electrical codes
Motor
Hi Performance
Rating
2.1 H.P.,
1.4 H.P.,
and 1.25 H.P.
50'
100'
115V Power Line
150'
200'
12
10
8
8
AIR MASSAGE SYSTEM:
The air bath should be installed on a 10 vac, 15 or 0 amp dedicated circuit. The circuit should be hard-wired
from the electrical power supply panel. The circuit must be a three (3) wire circuit from the electrical supply panel.
A grounded neutral wire and a third wire, earth ground, are essential.
!
USE 15 OR 20 AMP
GFCI OUTLET
AIR BLOWER
CHROMATHERAPY LIGHT
CONTROL BOX (OPTIONAL)
B
L
A
C
K
W
H
IT
E
120 VAC
GND.