American Standard Colony PRO 7075.000 Installation Instructions Manual Download Page 3

- 2 -

2

3

4

•  Operate LIFT KNOB 

(1)

 to verify that

STOPPER 

(2)

 opens and closes.

CHECK OPERATION OF POP-UP

MAKE WATER SUPPLY AND WASTE CONNECTIONS

M965766 (8/16)

• Push TAIL PIECE

 (11) 

down into TRAP

 (C) 

(threaded end up).

•  Thread LOCKNUT

 (5)

, WASHER 

(4) 

and GASKET

 (3)

(Bevel side up) onto DRAIN BODY 

(10)

.

• Apply a bead of PUTTY

 (D) 

to underside of FLANGE

 (2)

.

•  Feed DRAIN BODY 

(10) 

up through SINK

 (A)

 and thread

the FLANGE 

(2) 

fully onto DRAIN BODY

 (10)

.

•  Tighten LOCKNUT

 (5) 

firmly, keeping the pivot rod hole pointed

towards the back of the sink.

•  Assemble PIVOT ROD

 (9) 

as shown in

 Figure-2a.

Notice the position of the CONCAVE WASHER

 (G)

.

•  Insert PIVOT ROD

 (9)

 into DRAIN BODY

 (10)

 and tighten

PIVOT NUT

 (F)

.

•  Pull TAIL PIECE 

(11)

 up and thread tightly into

DRAIN BODY 

(10)

.

•  Position EXTENSION ROD 

(7)

 onto POP-UP ROD

 (E) 

and tighten

THUMBSCREW

 (6)

.

•  Remove one end of CLIP

 (8)

 from PIVOT ROD

 (9) 

by squeezing ENDS TOGETHER WHILE SLIDING.

•  Insert PIVOT ROD

 (9)

 into second or third hole in EXTENSION ROD

 (7)

 and reassemble CLIP 

(8)

.

• DROP STOPPER

 (1) 

into DRAIN BODY

 (10)

.

•  Adjust stopper height by repositioning EXTENSION ROD

 (7) 

and tightening THUMBSCREW

 (6)

.

INSTALL POP-UP DRAIN

1

APPROX. 20"

2

COLD

HOT

3/8" COMPRESSION

RED

BAND

BLUE

BAND

•  Connect FLEXIBLE SUPPLIES 

(1, 2)

 directly to wall supplies.

Connection on fitting supplies are 3/8

"

 compression.

Connect left SUPPLY 

(1)

 to Hot (Marked with a Red Band)

and right supply to COLD 

(2)

 wall supply.

•  Faucet supplies are 20

"

 long from faucet base.

Note: If additional supply length is required, installer must
purchase additional parts separately.
Important: If SUPPLY HOSES (1, 2) are to long, loop as
illustrated to avoid kinking.

•  Connect 1-1/4” O.D. tailpiece on POP-UP DRAIN to

waste outlet.

1-1/4"

6

E

D

7

8

9

C

F

2

A

1

3

4

5

10

11

2a

F

G

2

1

P-2, P-2B - 7075.050

Summary of Contents for Colony PRO 7075.000

Page 1: ...Way South Portland Maine Phone 207 772 8364 Fax 207 773 4571 PLUMBING HEATING COOLING AND INDUSTRIAL SUPPLIES SERVING NEW ENGLAND NEW YORK SINCE 1866 WARREN MECHANICAL HARTLEY BLOCK O M FIXTURES 06 08...

Page 2: ...MENDED TOOLS 1 M965766 8 16 INSTALL FAUCET COLONY PRO SINGLE CONTROL CENTERSET LAVATORY FAUCET INSTALLATION INSTRUCTIONS 7075 054 7075 055 7075 056 7075 050 7075 004 7075 005 7075 006 7075 002 7075 00...

Page 3: ...ROD E and tighten THUMBSCREW 6 Remove one end of CLIP 8 from PIVOT ROD 9 by squeezing ENDS TOGETHER WHILE SLIDING Insert PIVOT ROD 9 into second or third hole in EXTENSION ROD 7 and reassemble CLIP 8...

Page 4: ...MIT SAFETY STOP By restricting HANDLE rotation and limiting the amount of hot water allowed to mix with the cold the HOT LIMIT SAFETY STOP 8 reduces risk of accidental scalding To lower the maximum ho...

Page 5: ...0070A AERATOR 0 5 GPM 4 M965766 8 16 COLONY PRO SINGLE CONTROL CENTERSET LAVATORY FAUCET MODEL NUMBERS Replace the YYY with appropriate finish code POLISHED CHROME 002 LEGACY BRONZE 278 SATIN NICKEL 2...

Page 6: ...ME A112 18 1 CSA B125 1 WaterSense 1 5 gpm 5 7 L min 2 0 gpm 7 6 L min S 9600 P Origins Shower Valve S 9600TS P Origins Tub Shower Valve S 9601 P Origins Shower System S 9602 P Origins Tub Shower Syst...

Page 7: ...S 9600TS P Ref 42 1067 mm S 9601 P S 9600 P H Male 1 2 NPT fitting must protrude 4 from finished wall I 5 1 2 140 mm J 2 1 2 64 mm K 2 3 4 70 mm L 2 1 8 54 mm M 5 3 4 146 mm N 2 1 2 64 mm FLOOR FLOOR...

Page 8: ...062 B Brass K Tub Spout 060 Parts Breakdown A HOT Water Supply COLD Water Supply B C D E F I F G K H J Notes 1 Apply a bead of silicone around the perimeter of all shower trim installed flush to the...

Page 9: ...lve and secure with set screw H Install plug button I H I D 1 2 5 Install tub spout K to pipe fitting Turn clockwise to secure 1 K 2 6 Attach shower arm B and flange C to vertical shower pipe Turn clo...

Page 10: ...e approximately 3 4 turn to put valve in hot position 1 Turn diverter handle left for tub spout operation Operation Diverter Control S 9600TS P and S 9602 P Only 2 Turn diverter handle right for showe...

Page 11: ...information Compliance Certified by CSA Group Modifications Note Append appropriate suffix to model number ASME A112 18 1 CSA B125 1 WaterSense 1 5 gpm 5 7 L min 2 0 gpm 7 6 L min S 9603 PLR Origins H...

Page 12: ...easurements A 3 76 mm B 3 1 2 89 mm C Male 1 2 NPT fitting must protrude 3 8 from finished wall D Shower Valve Hole Size Min 3 76 mm Max 4 102 mm E 3 5 8 92 mm F Rough in 2 3 8 1 2 60 mm 13 mm G Ref 3...

Page 13: ...tyle Note Append STN to part number for Satin Nickel finish Replacement Parts Item Description Part Number A B Handle Assembly RTS 063 C Dome Cover T 19 D E Shower Escutcheon Kit Standard S 9600 PLR E...

Page 14: ...ot holes into studs or wood blocking With slide bar J in position secure to wall using screws I Attach slide bar ends J1 to bar flanges J 3 3 3 I J1 1 2 3 Install dome cover C to valve Turn clockwise...

Page 15: ...ly 3 4 turn to put valve in hot position Installation 9 Press tabs on wall ell flange Install wall ell K to pipe fitting Turn clockwise to secure 2 3 K 1 1 10 Attach hand shower H to hose N Attach hos...

Page 16: ...ion Volume Control 1 Turn volume control handle left for high flow 2 Turn volume control handle right for low flow Troubleshooting Chart Problem Cause Solution Finish is spotting Elements in water sup...

Page 17: ...gle Handle Kitchen Faucet MODEL HANDLE FINISH 8707 Lever Chrome Aerator 3919 Side Spray 1860 Chrome Cartridge 121549 Optional Deck Plate Handle Kit 121521 Screw Red Blue Plug Button Kit 40001 Side Esc...

Page 18: ...ON THE UNDERSIDE OF THE HANDLE AFTER THE HANDLES HAVE BEEN REMOVED UNSCREW THE HANDLE NUTS AND PULL OUT ON THE CARTRIDGE ZURN WILL SUPPLY HANDLE PORT PLUGS ZURN PART 61094001 AT YOUR REQUEST 8 REPLACE...

Page 19: ...DGE SHUT THE WATER OFF LOOSEN THE HANDLE NUTS AND PULL UP ON THE CARTRIDGE REPLACEMENT PARTS COLD WATER CARTRIDGE 59517001 HOT WATER CARTRIDGE 59517002 INDEX BUTTONS G60500 STOP PLUGASSEMBLY G67807 IT...

Reviews: