AQUASPEC FAUCETS

MODEL - Z84300 SERIES

SINK FAUCET

TECHNICAL INFORMATION

MAXIMUM PRESSURE:

  125 PSI

MAXIMUM TEMPERATURE:

  180

F

F

HANDLE NUT TORQUE:

  15-20 FT - LBS.

CARTRIDGE STYLE:

  QUARTER TURN CERAMIC DISK

INSTALLATION INSTRUCTIONS

1. 1/2” IP NIPPLE SHOULD PROTRUDE 3/8” FROM THE FINISHED WALL ON 8” CENTERS.  SUPPLY PIPES SHOULD BE

SECURED TO SUPPORT THE FAUCET.

2. APPLY PIPE SEALANT TO 1/2” THREADS OF SUPPLY PIPE AND SCREW SUPPLY ARM ASSEMBLY (ITEM #5) ONTO PIPE.

POSITION SUPPLIES SO THAT THE BODY CONNECTIONS END UP AT 8” CENTERS ON A HORIZONTAL PLANE.

3. INSERT SINK FAUCET BODY (ITEM #4) TO SUPPLY ARMS PLACING GASKET (ITEM #5A) BETWEEN BODY AND SUPPLY

ARM.

4. ASSEMBLE SPOUT TO BODY USING HARDWARE.

5. INSTALL WALL BRACE BY SCREWING THE SUPPORT ROD INTO THE THREADED SPOUT CONNECTION.  ADJUST THE

SUPPORT ROD TO DESIRED LENGTH AND SECURE TO FINISHED WALL USING THE TWO WOOD SCREWS PROVIDED.

NOTE:  SUPPORT FOR FINISHED WALL IS RECOMMENDED WHERE WALL BRACE MOUNTS FOR MAXIMUM SUPPORT.

6. TURN WATER SUPPLY ON AND OPERATE FAUCET CHECKING FOR LEAKS.

7. IT MAY BE NECESSARY TO SHUT WATER OFF AND REMOVE CARTRIDGES TO CLEAN SUPPLY LINES.  CARTRIDGES

CAN BE REMOVED BY FIRST REMOVING THE HANDLES.  COLOR INDEXES CAN BE REMOVED BY INSERTING A PIN
INTO THE HOLE ON THE UNDERSIDE OF THE HANDLE.   AFTER THE HANDLES HAVE BEEN REMOVED UNSCREW THE
HANDLE NUTS  AND PULL OUT ON THE CARTRIDGE.  ZURN WILL SUPPLY HANDLE PORT PLUGS (ZURN PART
#61094001) AT YOUR REQUEST.

8. REPLACE CARTRIDGES IN BODY AND HAND TIGHTEN HANDLE NUTS.  PLACE HANDLES ON THE CARTRIDGE STEM

AND LOCATE THEM AS DESIRED.  TIGHTEN HANDLE NUTS.

9. REPLACE HANDLE SCREWS AND COLOR INDEX BUTTON.

10. IF NECESSARY, INSTALL AERATOR INTO SPOUT AND HAND TIGHTEN.  IT MAY BE NECESSARY TO UNSCREW  AND

CLEAN AERATOR AT START-UP.

SERVICE INSTRUCTIONS

1. YOUR ZURN AQUASPEC FAUCET IS FURNISHED WITH INTEGRAL SUPPLY STOPS (ITEM #4B) TO PROVIDE A COMPLETE

SHUT OFF OF THE WATER SUPPLY.  TURN SCREW STOPS INTO BODY USING 5/16” HEX KEY WRENCH UNTIL WATER
SHUTS OFF COMPLETELY.  TURN STOP NO MORE THAN THREE (3) COMPLETE TURNS TO ACTIVATE WATER FLOW.

CAUTION-FOR INSTALLATION WITH ATMOSPHERIC VACUUM BREAKERS (AVB’S)

THIS DEVICE SHOULD NEVER

BE USED IN INSTALLATIONS THAT ARE UNDER CONTINUOUS PRESSURE WHEN INSTALLED WITH SPOUTS HAVING
ATMOSPHERIC VACUUM BREAKERS (AVB’S). THEREFORE, NEVER PLACE A SELF-CLOSING, SHUT-OFF VALVE DOWN-
STREAM OF AN AVB.

Form #

 CF732

Date:

 12/20/11

C.N. No.

 128437

Rev.

 F

ZURN INDUSTRIES, LLC. 

 COMMERCIAL BRASS OPERATION 

 5900 ELWIN BUCHANAN DRIVE 

 SANFORD NC 27330

Phone: 1-800-997-3876 

 Fax: 919-775-3541 

 World Wide Web: www.zurn.com

In Canada: ZURN INDUSTRIES LIMITED 

 3544 Nashua Drive 

 Mississauga, Ontario L4V1L2 

 Phone: 905-405-8272 Fax: 905-405-1292

P-6 MOP SINK - ZURN Z843M1

Summary of Contents for Colony PRO 7075.000

Page 1: ...Way South Portland Maine Phone 207 772 8364 Fax 207 773 4571 PLUMBING HEATING COOLING AND INDUSTRIAL SUPPLIES SERVING NEW ENGLAND NEW YORK SINCE 1866 WARREN MECHANICAL HARTLEY BLOCK O M FIXTURES 06 08...

Page 2: ...MENDED TOOLS 1 M965766 8 16 INSTALL FAUCET COLONY PRO SINGLE CONTROL CENTERSET LAVATORY FAUCET INSTALLATION INSTRUCTIONS 7075 054 7075 055 7075 056 7075 050 7075 004 7075 005 7075 006 7075 002 7075 00...

Page 3: ...ROD E and tighten THUMBSCREW 6 Remove one end of CLIP 8 from PIVOT ROD 9 by squeezing ENDS TOGETHER WHILE SLIDING Insert PIVOT ROD 9 into second or third hole in EXTENSION ROD 7 and reassemble CLIP 8...

Page 4: ...MIT SAFETY STOP By restricting HANDLE rotation and limiting the amount of hot water allowed to mix with the cold the HOT LIMIT SAFETY STOP 8 reduces risk of accidental scalding To lower the maximum ho...

Page 5: ...0070A AERATOR 0 5 GPM 4 M965766 8 16 COLONY PRO SINGLE CONTROL CENTERSET LAVATORY FAUCET MODEL NUMBERS Replace the YYY with appropriate finish code POLISHED CHROME 002 LEGACY BRONZE 278 SATIN NICKEL 2...

Page 6: ...ME A112 18 1 CSA B125 1 WaterSense 1 5 gpm 5 7 L min 2 0 gpm 7 6 L min S 9600 P Origins Shower Valve S 9600TS P Origins Tub Shower Valve S 9601 P Origins Shower System S 9602 P Origins Tub Shower Syst...

Page 7: ...S 9600TS P Ref 42 1067 mm S 9601 P S 9600 P H Male 1 2 NPT fitting must protrude 4 from finished wall I 5 1 2 140 mm J 2 1 2 64 mm K 2 3 4 70 mm L 2 1 8 54 mm M 5 3 4 146 mm N 2 1 2 64 mm FLOOR FLOOR...

Page 8: ...062 B Brass K Tub Spout 060 Parts Breakdown A HOT Water Supply COLD Water Supply B C D E F I F G K H J Notes 1 Apply a bead of silicone around the perimeter of all shower trim installed flush to the...

Page 9: ...lve and secure with set screw H Install plug button I H I D 1 2 5 Install tub spout K to pipe fitting Turn clockwise to secure 1 K 2 6 Attach shower arm B and flange C to vertical shower pipe Turn clo...

Page 10: ...e approximately 3 4 turn to put valve in hot position 1 Turn diverter handle left for tub spout operation Operation Diverter Control S 9600TS P and S 9602 P Only 2 Turn diverter handle right for showe...

Page 11: ...information Compliance Certified by CSA Group Modifications Note Append appropriate suffix to model number ASME A112 18 1 CSA B125 1 WaterSense 1 5 gpm 5 7 L min 2 0 gpm 7 6 L min S 9603 PLR Origins H...

Page 12: ...easurements A 3 76 mm B 3 1 2 89 mm C Male 1 2 NPT fitting must protrude 3 8 from finished wall D Shower Valve Hole Size Min 3 76 mm Max 4 102 mm E 3 5 8 92 mm F Rough in 2 3 8 1 2 60 mm 13 mm G Ref 3...

Page 13: ...tyle Note Append STN to part number for Satin Nickel finish Replacement Parts Item Description Part Number A B Handle Assembly RTS 063 C Dome Cover T 19 D E Shower Escutcheon Kit Standard S 9600 PLR E...

Page 14: ...ot holes into studs or wood blocking With slide bar J in position secure to wall using screws I Attach slide bar ends J1 to bar flanges J 3 3 3 I J1 1 2 3 Install dome cover C to valve Turn clockwise...

Page 15: ...ly 3 4 turn to put valve in hot position Installation 9 Press tabs on wall ell flange Install wall ell K to pipe fitting Turn clockwise to secure 2 3 K 1 1 10 Attach hand shower H to hose N Attach hos...

Page 16: ...ion Volume Control 1 Turn volume control handle left for high flow 2 Turn volume control handle right for low flow Troubleshooting Chart Problem Cause Solution Finish is spotting Elements in water sup...

Page 17: ...gle Handle Kitchen Faucet MODEL HANDLE FINISH 8707 Lever Chrome Aerator 3919 Side Spray 1860 Chrome Cartridge 121549 Optional Deck Plate Handle Kit 121521 Screw Red Blue Plug Button Kit 40001 Side Esc...

Page 18: ...ON THE UNDERSIDE OF THE HANDLE AFTER THE HANDLES HAVE BEEN REMOVED UNSCREW THE HANDLE NUTS AND PULL OUT ON THE CARTRIDGE ZURN WILL SUPPLY HANDLE PORT PLUGS ZURN PART 61094001 AT YOUR REQUEST 8 REPLACE...

Page 19: ...DGE SHUT THE WATER OFF LOOSEN THE HANDLE NUTS AND PULL UP ON THE CARTRIDGE REPLACEMENT PARTS COLD WATER CARTRIDGE 59517001 HOT WATER CARTRIDGE 59517002 INDEX BUTTONS G60500 STOP PLUGASSEMBLY G67807 IT...