In case of difficulty

If you have difficulty with your Comfort Control, please try the suggestions below.
Most problems can be corrected quickly and easily.

Display is blank

Check circuit breaker and reset if necessary.

Make sure power switch at heating & cooling system is on.

Make sure furnace door is closed securely.

Temperature 
settings do not
change

Make sure heating and cooling temperatures are set to acceptable ranges:

Heat: 40° to 90°F (4.5° to 32°C).

Cool: 60° to 99°F (16° to 37°C).

Heating system
does not respond
(“Heat On”
appears on
screen)

Check for 24 VAC at the equipment on the secondary side of the trans-
former between power and common. If voltage is not present, check the
heating equipment to find the cause of the problem.

Check for 24 VAC between the heat terminal (W) and the transformer 
common. If 24 VAC is present, the Comfort Control is functional. Check 
the heating equipment to find the cause of the problem.

Check for loose or broken wires between the Comfort Control and the 
heating equipment.

Cooling system
does not respond
(“Cool On”
appears on
screen)

Check for 24 VAC at the equipment on the secondary side of the trans-
former between power and common. If voltage is not present, check the
cooling equipment to find the cause of the problem

Check for 24 VAC between the cooling terminal (Y) and the transformer
common. If 24 VAC is present, the Comfort Control is functional. Check 
the cooling system to find the cause of the problem.

Check for loose or broken wires between the Comfort Control and the 
cooling equipment.

Fan does not
turn on in a call
for heat

Check Installer Setup, Function 3 (Fan Control), to make sure the fan con-
trol is properly set to match the type of system (see page 7).

Heat/cool both on
at same time, or
heat does not
turn off

Check Installer Setup, Function 1 (System Type), to make sure it is set to
match the installed heating/cooling equipment (see page 7).

Check to make sure heating and cooling wires are not shorted together.

 

Summary of Contents for ACONT600AF11MA

Page 1: ...ACONT600AF11MA Programmable Comfort Control Installation Instructions 11 HD02D10 1...

Page 2: ...rienced technician Read these instructions carefully Failure to follow these instructions can dam age the product or cause a hazardous condition Check the ratings in this booklet to verify that this p...

Page 3: ...s or chimneys Unheated uncooled areas such as an outside wall behind the Comfort Control NO NO NO Installation Pre installation checklist 2 Wallplate installation 3 Wiring 4 Wiring diagrams 5 Power op...

Page 4: ...uide Wall anchors and mounting screws 2 each AA alkaline batteries 2 Programmable Comfort Control wallplate attached to back Required tools supplies No 2 Phillips screwdriver Small pocket screwdriver...

Page 5: ...n wall level and mark hole positions with pencil 4 Drill holes at marked positions as shown below then tap in supplied wall anchors 5 Place wallplate over anchors insert and tighten mounting screws In...

Page 6: ...nnect to secondary side of heating system transformer Rc Cooling power Connect to secondary side of cooling system transformer Terminal block NOTES R Rc terminals In single transformer system leave me...

Page 7: ...ystem SINGLE STAGE GAS FURNACE SINGLE STAGE COOLING SINGLE STAGE AIR CONDITIONER SINGLE STAGE GAS FURNACE 24VAC HOT 24VAC 600 COMFORT CONTROL TERMINAL BLOCK FAN COOLING HEATING FACTORY INSTALLED JUMPE...

Page 8: ...back of thermostat optional if AC powered Battery Backup Power The Comfort Control can be powered by backup batteries when used with AC power During power interruptions the batteries will save time d...

Page 9: ...7 8 10 11 or 12 CPH 3 Recommended for most compressors Other cycle rate options 1 2 4 5 or 6 CPH 0 Manual changeover Heat Cool Off 1 Auto changeover Heat Cool Auto Off See page 10 2 Auto changeover on...

Page 10: ...ee page 7 0 Compressor and fan turn off 1 Compressor and fan turn on 0 Fan turns off 1 Fan turns on 71 Software revision number major revisions 72 Software revision number minor revisions 73 Configura...

Page 11: ...on after shutdown This feature forces the compressor to wait for a few minutes before restarting During the wait time the message Cool On or Heat On heat pumps only will flash on the display When the...

Page 12: ...temperature Low battery warning Current time day Current program period Wake Leave Return Sleep Temperature setting System status On when calling for heating or cooling flashes when waiting for compre...

Page 13: ...uipment to find the cause of the problem Check for loose or broken wires between the Comfort Control and the heating equipment Cooling system does not respond Cool On appears on screen Check for 24 VA...

Page 14: ...tem Setting to Manual or Auto Changeover see page 7 Heat On is not displayed Change the System Setting to Heat and set the temperature level above the current room temperature Cool On is not displayed...

Page 15: ...Pub No 11 HD02D10 1 07 06 6200 Troup Highway Tyler TX 75711 9010 U S Registered Trademark Patents Pending 2006 American Standard All rights reserved...

Reviews: