Auto Changeover (Setup Function 12)

Auto Changeover is a feature used in 
climates where both air conditioning and
heating are used on the same day.When the
system is set to Auto, the Comfort Control
automatically selects heating or cooling
depending on the indoor temperature.

Heat and cool settings must be at least 3
degrees apart.The Comfort Control will 
automatically adjust settings to maintain this
3-degree separation (called “deadband”).

The 3-degree separation between heating
and cooling set temperatures is fixed, and
cannot be changed.

Built-in compressor protection (Setup Function 15)

This feature helps prevent damage to the
compressor in your air conditioning or heat
pump system.

Damage can occur if the compressor is re-
started too soon after shutdown.This feature
forces the compressor to wait for a few 
minutes before restarting.

During the wait time, the message Cool On
or Heat On (heat pumps only) will flash on
the display.When the safe wait time has
elapsed, the message stops flashing and the
compressor turns on.

Message flashes until safe
restart time has elapsed

Adaptive Intelligent Recovery™ (Setup Function 13)

Adaptive Intelligent Recovery eliminates guesswork when setting your schedule. It
allows the Comfort Control to “learn” how long your furnace and air conditioner
take to reach the temperature you want.

Just set your program schedule to the time you want the house to reach your
desired temperature.The Comfort Control then turns on the heating or cooling at
just the right time to reach your scheduled temperature at your scheduled time.

For example: Set the Wake time to 6 am, and the temperature to 70°.The heat will
come on before 6 am, so the temperature is 70° by the time you wake at 6.

Summary of Contents for ACONT600AF11MA

Page 1: ...ACONT600AF11MA Programmable Comfort Control Installation Instructions 11 HD02D10 1...

Page 2: ...rienced technician Read these instructions carefully Failure to follow these instructions can dam age the product or cause a hazardous condition Check the ratings in this booklet to verify that this p...

Page 3: ...s or chimneys Unheated uncooled areas such as an outside wall behind the Comfort Control NO NO NO Installation Pre installation checklist 2 Wallplate installation 3 Wiring 4 Wiring diagrams 5 Power op...

Page 4: ...uide Wall anchors and mounting screws 2 each AA alkaline batteries 2 Programmable Comfort Control wallplate attached to back Required tools supplies No 2 Phillips screwdriver Small pocket screwdriver...

Page 5: ...n wall level and mark hole positions with pencil 4 Drill holes at marked positions as shown below then tap in supplied wall anchors 5 Place wallplate over anchors insert and tighten mounting screws In...

Page 6: ...nnect to secondary side of heating system transformer Rc Cooling power Connect to secondary side of cooling system transformer Terminal block NOTES R Rc terminals In single transformer system leave me...

Page 7: ...ystem SINGLE STAGE GAS FURNACE SINGLE STAGE COOLING SINGLE STAGE AIR CONDITIONER SINGLE STAGE GAS FURNACE 24VAC HOT 24VAC 600 COMFORT CONTROL TERMINAL BLOCK FAN COOLING HEATING FACTORY INSTALLED JUMPE...

Page 8: ...back of thermostat optional if AC powered Battery Backup Power The Comfort Control can be powered by backup batteries when used with AC power During power interruptions the batteries will save time d...

Page 9: ...7 8 10 11 or 12 CPH 3 Recommended for most compressors Other cycle rate options 1 2 4 5 or 6 CPH 0 Manual changeover Heat Cool Off 1 Auto changeover Heat Cool Auto Off See page 10 2 Auto changeover on...

Page 10: ...ee page 7 0 Compressor and fan turn off 1 Compressor and fan turn on 0 Fan turns off 1 Fan turns on 71 Software revision number major revisions 72 Software revision number minor revisions 73 Configura...

Page 11: ...on after shutdown This feature forces the compressor to wait for a few minutes before restarting During the wait time the message Cool On or Heat On heat pumps only will flash on the display When the...

Page 12: ...temperature Low battery warning Current time day Current program period Wake Leave Return Sleep Temperature setting System status On when calling for heating or cooling flashes when waiting for compre...

Page 13: ...uipment to find the cause of the problem Check for loose or broken wires between the Comfort Control and the heating equipment Cooling system does not respond Cool On appears on screen Check for 24 VA...

Page 14: ...tem Setting to Manual or Auto Changeover see page 7 Heat On is not displayed Change the System Setting to Heat and set the temperature level above the current room temperature Cool On is not displayed...

Page 15: ...Pub No 11 HD02D10 1 07 06 6200 Troup Highway Tyler TX 75711 9010 U S Registered Trademark Patents Pending 2006 American Standard All rights reserved...

Reviews: