background image

6

7301793-100 Rev. C

16

INSTALL SINK APRON

1. Hold APRON up against SINK and flush against finished wall.

2. Mark a line with a pencil on the wall about 6" long as shown on 

both sides of the APRON..

3. Remove the APRON. Clean the wall where the APRON 

BRACKETS supplied with SINK are to be applied. Peel off the 

protective strip from the back of the APRON BRACKETS. Apply the 

two APRON BRACKETS to the finished wall parallel to the pencil 

marks as shown in the illustration below.

OPTIONAL MOUNTING. (SCREWS AND ANCHORS NOT 

SUPPLIED) Use Brackets to mark pilot holes on wall. Drill holes for 

ANCHORS. Peel off the protective strip from the back of the APRON 

BRACKETS. Apply the two APRON BRACKETS to the finished wall 

parallel to the pencil marks as shown and aligned with the mounting holes. 

See illustration below. Install SCREWS and tighten.    

4. Clean off the pencil marks from wall. 

6"

(152mm)

APRON

SINK

6. Retain APRON with THUMB NUT. Finger tight only.

5. Position APRON under SINK and against finished wall alinging 

EYEBOLT with hole in APRON.

THUMB NUT

EYEBOLT

APRON

APRON

IMPORTANT: SAVE ALL INSTALLATION INSTRUCTIONS FOR FUTURE USE 

1/2"

(13mm)

PENCIL MARK

APRON

CLEAN WALL

PROTECTIVE

STRIP

Summary of Contents for 9118.111

Page 1: ... INSTALLATION INSTRUCTIONS Pr o d u c t n a m e s l i s t e d h e r e i n a r e t r a d e m a r k s o f A S A m e r i c a I n c A S A m e r i c a I n c 2 01 2 14 3 4 375mm 17 432mm 4 3 4 121mm 5 8 14mm 1 5 8 41mm 20 509mm 4 3 4 120mm 8 203mm 1 2 DIA 13mm FINISHED WALL BASE MOUNT DETAIL FINISHED FLOOR FINISHED FLOOR FINISHED FLOOR 26 1 8 663mm 36 914mm 36 1 2 927mm 36 1 2 927mm 40 1 8 1020mm 2 3 4 ...

Page 2: ...f mounting surface 2 Assemble C WASHER 4 STAR WASHER 5 and LOCKNUT 6 onto threads of SPOUT SHANK 3 from underside of mounting surface 3 Align FAUCET and tighten LOCKNUT 6 1 Apply plumber s putty to the underside of flange Install GRID DRAIN into drain outlet 2 From the underside of SINK install RUBBER GASKET flat side up and FRICTION GASKET onto GRID DRAIN threads Apply sealent to threads of GRID ...

Page 3: ... BRACKET Replace NYLOCK NUT WASHER tighten both ends Do not over tighten chinaware could become damaged NYLOCK NUT AND WASHER HANGER STUD COLD WATER OR TEMPERED WATER 3 8 SUPPLY HOT MIXING VALVE MIXING VALVE SCREWS MOUNTING PLATE ELECTRONIC BOX ELECTRONIC BOX COLD 1 2 1 Connect SUPPLY NUT 1 from SPOUT assembly to nipple on top of ENCLOSURE 2 Tighten with adjustable wrench to make a water tight con...

Page 4: ...e COVER from MIXING VALVE 2 Install FIBER SEAL WASHER 4 on MIXING VALVE NIPPLE 3 Hold MIXING VALVE 1 in place with one hand and with your other hand thread SWIVEL NUT 2 onto MIXING VALVE NIPPLE 3 Use an adjustable wrench to tighten SWIVEL NUT 2 3 Place MIXING VALVE BOX onto MOUNTING PLATE Align BOX with mounting holes Attach with SCREWS provided 4 Replace COVER and tighten securely NOTE For comple...

Page 5: ...ea only 1 905 3061093 SELECTRONIC Proximity ICU Faucet Certified to comply with ASME A112 18 1M 2011 American Standard To learn more about American Standard Faucets visit our website at www us amstd com or U S customer s e mail us at faucetsupport amstd com For Parts Service Warranty or other Assistance please call 1 800 442 1902 In Canada 1 800 387 0369 NOTE TO INSTALLER Please give this manual t...

Page 6: ...TING SCREWS AND ANCHORS NOT SUPPLIED Use Brackets to mark pilot holes on wall Drill holes for ANCHORS Peel off the protective strip from the back of the APRON BRACKETS Apply the two APRON BRACKETS to the finished wall parallel to the pencil marks as shown and aligned with the mounting holes See illustration below Install SCREWS and tighten 4 Clean off the pencil marks from wall 6 152mm APRON SINK ...

Page 7: ...E LIABLE FOR THE COST OF REPAIR OR REPLACEMENT OF ANY INSTALLATION MATERIALS INCLUDING BUT NOT LIMITED TO TILES MARBLE ETC American Standard will not be responsible for any other incidental or consequential damages attributable to a product defect or to the repair or exchange of a defective product all of which are expressly excluded from this limited warranty This limited warranty does not cover ...